
REPORT MENU OPTIONS
Note: ROOM CO and tightness are accessed via TEST position.
Rotate dial to TEST to find ROOM CO and TIGHTNESS Tests.
PRESSURE & TEMPERATURE TESTING
WARNING
Never take a pressure reading without knowing the maximum pressure
present. Your analyser pressure transducer is rated at 160 mbar with a
maximum over range of 400 mbar.
Rotate dial to Prs/Temp and use the black connectors & manometer hose to
connect to P1 for single pressure or P1 & P2 for different pressure.
Pressure connection
P2
-
Differential
Pressure
connection P1
KANE958 MANUAL 21
Print currently selected report
Use to find next available report if
available
Use to find previously selected report
once navigation begins
Return to main menu