K&S KS 10000E Instruction Manual Download Page 4

3

- Please set the generator on a flat hard horizontal surface. To reduce vibration 

during operation and to avoid damage to the surface, where the generator is 

installed, it is equipped with dampers.

- Please don’t use the generator near flammable gases, liquids or dust. When 

using the generator exhaust system gets very hot. This may cause fire or 

explosion of these materials.

- Be sure to follow cleanliness and good lighting in the work area. Clutter and 

poor lighting may cause an injury.

- Do not let the presence of unauthorized persons, children or animals when 

working with generator. If necessary, make sure to fencing the working area.

- Please use safety shoes and protective gloves when working with generator.

2.2. ELECTRICAL SAFETY

- The generator produces electricity that may lead to an electric shock while 

neglecting compliance regulations.

- In the high humidity level conditions generator exploit is prohibited. Keep the 

generator in a dry place only.

- Avoid direct contact with grounded surfaces (pipes, radiators, etc.).

- Do not allow moisture in the generator. The water inside the device increases 

the risk of an electric shock.

- Be careful when working with power cables. Immediately replace it in case of 

damage, as damaged wire increases the risk of electric shock.

- All connecting the generator to the network must be made by certified 

electrician in accordance with all electrical rules and regulations.

- Connect the generator to the protective ground before operation.

- Do not connect or disconnect a generator to electricity consumers, which are 

placed in water on a wet or damp soil.

- Do not touch parts of the generator under voltage.

- Connect the generator to those customers only which meet the electrical 

characteristics and the rated power of the generator.

- Store all electrical equipment dry and clean. Wires with damaged or spoiled 

insulation should be replaced. You should also replace worn, damaged or rusty 

contacts.

2.3. PERSONAL SAFETY

- Be careful. Do not operate the generator, if you are tired, under the influence of 

drugs or alcohol. Inattention may cause a serious injury.

- Do not wear loose clothing or jewelry when working. Long hair, jewelry or loose 

clothing may get into the moving parts of the generator and cause an injury.

- Avoid inadvertent start. Make sure to set the switch to Off when you turn off 

the generator.

- Make sure no outsider objects are on the generator when it is turned on. Do not 

overload the generator, use it only for the purpose. Proper use of the generator 

will do the job for which it is designed better and safer. 

- Using device for other purposes deprives the right for free warranty. It is not allowed 

to sit or stand on the generator.

- Always keep a stable position and balance when starting the generator.

- Use safety equipment. Always wear goggles, a mask, non-slip sole shoes, 

protective helmet, headphones.

The device generates electricity. Follow safety precautions to avoid 

electric shock.

!

!

ATTENTION - DANGER!

Summary of Contents for KS 10000E

Page 1: ...nerator Dual fuel generator Instruction Please read this manual before use ENG KS 3000 KS 3000E KS 7000 KS 7000E KS 7000E 3 KS 7000E ATS KS 7000E 3 ATS KS 7000E 1 3 KS 10000E 1 3 KS 10000E KS 10000E 3...

Page 2: ...Generator panel for models KS 7000E 1 3 KS 10000E 1 3 14 9 4 Digital display of gasoline generators 15 10 COMMISSIONING 15 11 BEFORE STARTING 16 11 1 Check the fuel level 16 11 2 Check the oil level...

Page 3: ...egrity and avoid any possible injuries we strongly recommendYou to carefully read this manual before operating the generator ABBREVIATIONS MEANING KS Generator model Electro start G Dual fuel type LPG...

Page 4: ...ian in accordance with all electrical rules and regulations Connect the generator to the protective ground before operation Do not connect or disconnect a generator to electricity consumers which are...

Page 5: ...ng the tank all excessive fuel spillage are to be removed from the surface It is forbidden to use kerosene or other fuel types Observe the fuel tank refilling Do not allow overfilling All explosive an...

Page 6: ...manual before using the device g Do not touch the generator with wet or dirty hands h Follow fire safety rules do not use open flames near the generator i Please don t touch The muffler heats up when...

Page 7: ...rent models this table is different All charachtetistics are given in the Specifications Indicates the position of the fuel tap Position ON opened position OFF closed Note which direction you should o...

Page 8: ...switch 10 Fuel level indicator 11 Silencer 12 Alternator 13 Sparking plug 5 MAIN OVERVIEW pic 4 Manufacturerreservestherighttomakechangesand orimprovements indesign componentsset andtechnicalattribute...

Page 9: ...fuel generators additionally equipped with reductor for stable LPG supply pic 5 reductor LPG supply hose BE ADVISED It is strongly forbidden to use gasoline and LPG simultaneously While using a gasoli...

Page 10: ...69 94 69 94 Power output V 12 8 3 12 8 3 12 8 3 Engine model KS 230 KS 230 KS 230 Engine type gasoline 4strokecycle engine gasoline 4strokecycle engine LPG gasoline 4strokecycle engine Engine power hp...

Page 11: ...output V 12 8 3 12 8 3 12 8 3 Engine model KS 410 KS 410 KS 410 Engine type gasoline 4strokecycle engine gasoline 4strokecycle engine gasoline 4strokecycle engine Engine power hp 13 0 13 0 13 0 Crank...

Page 12: ...put V 12 8 3 12 8 3 12 8 3 Engine model KS 410 KS 410 KS 410 Engine type gasoline 4 stroke cycle engine gasoline 4 stroke cycle engine gasoline 4 stroke cycle engine Engine power hp 13 0 13 0 13 0 Cra...

Page 13: ...3 12 8 3 12 8 3 12 8 3 Engine model KS 460 KS 460 KS 460 KS 460 Engine type gasoline 4 stroke cycle engine gasoline 4 stroke cycle engine gasoline 4 stroke cycle engine gasoline 4 stroke cycle engine...

Page 14: ...R Engine start manual electro manual electro Power factor cos 1 0 8 1 0 8 Dimensions L W H mm 700 545 590 700 545 590 Weight kg 81 8 95 Protection class IP23M IP23M Altitude MAX m 1000 1000 Relative h...

Page 15: ...E ATS KS 10000E 3 ATS pic 7 1 LED display 2 Emergency circuit breaker 3 Sockets 4 Engine start key ON OFF 5 Direct current sockets 12V 6 Grounding 7 ATS switch 8 ATS indicator 9 ATS connectors 1 LEDdi...

Page 16: ...upplied without fuel Before the operation please fill the fuel Guidelines for filling are below Generators are supplied without motor oil The generator casing may contain residues of oil after tests c...

Page 17: ...or has not been used for a long time try charging the battery with the battery charger not included Fuel tank cap FILLTO HERE 12 ENGINE START Beforestartingtheenginepleasemakesurethatpowerofinstrument...

Page 18: ...the hose to the gas cylinder 2 Open the gas supply valve on the tank make sure there are no gas leaks 3 Usethevalveontheintegratedgearboxtoletoutairfromthehoseconnection press the lowering valve butt...

Page 19: ...so that it begins to supply power to devices connected to it When the power supply from the main network is renewed the generator system turns off and the voltage to consumers goes from the main netw...

Page 20: ...of electricity Power supply Power supply Electrical counter Electrical counter Neutral channel for connection Grounding Connectionofthegeneratorwiththebuilt inATStotheconsumersofelectricityandthecentr...

Page 21: ...IMPORTANT IMPORTANT 15 TECHNICAL MAINTENANCEWORKS Works specified in Technical maintenance section are to be regularily performed If the end user has no means for performing regular maintenance indepe...

Page 22: ...afety requirements and technical maintanance rules First of all this applies to use of lubricants gasoline and motor oils forbidden by the manufacturer device technical alterations equipment operation...

Page 23: ...tanance schedule To replace engine oil perform the following actions 1 Wearprotectiveglovestoavoidgettingoilontheskin 2 Place a drain oil holding tank under the engine 3 Turn the drain cap located in...

Page 24: ...ator operation every 10 hours in unusually dusty conditions pic 15 IMPORTANT wash wring soak wring 2 1 4 3 cap spring cap spring air filter air filter cap 19 SPARKPLUGSTECHNICALMAINTENANCE Spark plug...

Page 25: ...er gaswillevaporate Warning Generator is to remain ready for operation at all times Therefore in case of device malfunctions they are to be repaired before dismounting the generator for storage Before...

Page 26: ...ce between contacts is not nominal Clean or replace the plug Set proper distance between contacts Low engine power heavy starting Dirt in fuel tank Clean the fuel tank Dirt in the air filter Clean the...

Page 27: ...Radio 50 250 TV set 100 400 Refrigerator 100 150 Oven 1000 2000 Freezer 100 400 Drill 400 800 Hammer drill 600 1400 Grinding machine 300 1100 Circular saw 750 1600 Electro planer 400 1000 Electro jigs...

Page 28: ...ter ice formation provided there are foreign objects inside the unit If the product has been improperly installed and connected to the mains supply or misused If the claimed malfunction cannot be diag...

Page 29: ......

Page 30: ...Germany ks power de info dimaxgroup de Poland ks power pl info pl dimaxgroup de Ukraine ks power com ua sales ks power com ua CONTACTS...

Reviews: