background image

  

  

COMMISSIONING

COMMISSIONING

1. Fill the crankcase with engine oil. The recommended amount of oil for each model is indicated in the specification 

chart.

2. Check oil level with an oil dipstick. It should be between the MIN and MAX marks on the oil dipstick. 

3. Check fuel level.

4. Check the air filter for correct installation.

  

  

IN THE FIRST 20 OPERATING HOURS OF THE GENERATOR, THE FOLLOWING REQUIREMENTS SHOULD BE MET:

IN THE FIRST 20 OPERATING HOURS OF THE GENERATOR, THE FOLLOWING REQUIREMENTS SHOULD BE MET:

1.  During  commissioning,  do  not  connect  power  consumers,  the  power  of  which  exceeds  50%  of  the  nominal 

(operating) power of the device.

2. After the first 20 operating hours, be sure to change the oil. It is better to drain oil while the engine is still hot after 

operation to ensure quick and complete oil draining.

3. Check and clean the air filter, fuel filter and spark plug.

Before starting the generator, connect the ground wire to the 

ground terminal.

IMPORTANT!

This material is for informational purposes only and does not constitute a manual for installing 

the equipment or connecting it to the mains, but we strongly recommend that you read the 

instructions below. Equipment connection must always be carried out by a certified electrician 

responsible for the installation and electrical connection of the equipment according to local 

laws and regulations. The manufacturer assumes no liability for improper connection of the 

equipment or for any material or physical damage that may result from improper installation, 

connection or operation of the equipment.

  

  

E

NGINE START

NGINE START

Useful tip: If the engine stalls or does not start, turn the engine 

switch to the “ON” position, and then pull the manual starter. If 

the oil level indicator flickers for several ECONOMY MODE, add oil 

and restart the engine.

IMPORTANT!

Each time you start the generator, be sure to check oil and fuel 

level

IMPORTANT!

  

  

FOR MODEL KSB 21

FOR MODEL KSB 21

ii S S

1. Check oil level.

2. Check fuel level. 

3. Open the vent on the fuel cap to the “ON” position (Fig. 1).

4. Set the 3-in-1 switch to “Air choke” (Fig. 2). 

In this position: 

a.

 Ignition circuit is on. 

b. 

Fuel valve is open. 

c. 

Air choke is closed. 

(If the engine is warm, no need to turn to Choke position, turn immediately to “ON” position).

5. Pull the manual starter until a slight resistance is felt, then pull it toward you relatively sharply. Slowly turn the 

manual starter by hand, do not release it abruptly.

6. Set the 3-in-1 switch to “ON” (Fig. 2).

Fig. 1

Fig. 2

  

  

FOR MODELS KSB 30

FOR MODELS KSB 30

i i S, 

S, KSB 40

KSB 40iEiE S S

1. Check oil level.

2. Check fuel level. 

3. 

Set the ECONOMY MODE switch to “OFF” (for model KSB 40iE S).

4. 

Set the 3-in-1 switch to “Air choke” (Fig. 2). 

konner-sohnen.com

   

|

    8

Summary of Contents for KSB 21i S

Page 1: ...Please read this manual carefully before use OWNER S MANUAL EN Inverter Generator in Soundproof Housing KSB 21i S KSB 30i S KSB 40iE S...

Page 2: ...he front control panel and not less than 50 cm on each side including the upper part of the generator Keep unauthorized persons children and animals away from work area Wear safety shoes and gloves We...

Page 3: ...evices which can generate current pulses and direct energy towards the generator voltage stabilizers devices with electronic brakes on grid and hybrid inverters etc IMPORTANT The generator and power c...

Page 4: ...starter 1 Fuel tank cap 2 Transport handle only for model KSB 40iE S 3 Control panel 4 Manual starter 5 Brake 6 Battery only for model KSB 40iE S MODEL KSB 21 MODEL KSB 21ii S S MODELS MODELS KSB 30...

Page 5: ...fler 10 Carburetor 11 Air filter 12 Spark plug 13 Maintenance cover for motor oil change MODEL KSB 30 MODEL KSB 30ii S CONTROL PANEL S CONTROL PANEL MODEL MODEL KSB 40 KSB 40i i S S CONTROL PANEL CONT...

Page 6: ...dedtogroundthegeneratorbeforeoperatingitforthefirsttime Beforestartingthedevice remember that the total power of the connected power consumers should not exceed the nominal power of the generator TERM...

Page 7: ...he RESET button has a built in overload indicator When approaching the overload condition the indicator starts flashing The overload indicator lights up when the connected generator is overloaded the...

Page 8: ...O HERE Use only unleaded gasoline Using leaded gasoline can cause serious damage to the inside of the engine IMPORTANT Beforestartingtheengine Beforestartingtheengine makesurethattheratedpowerofpowerc...

Page 9: ...onsible for the installation and electrical connection of the equipment according to local laws and regulations The manufacturer assumes no liability for improper connection of the equipment or for an...

Page 10: ...ot connect two or more devices at a time The start up of many devices requires high power Devices should be connected one at a time according to their power rating Do not connect any power consumers w...

Page 11: ...om generators ensures total rated output power of these generators When the generators are connected in parallel the power loss is 0 2 kW of the total rated power that can be obtained During parallel...

Page 12: ...the filter element thoroughly in warm soapy water 6 Dry the sponge filter 7 Soak a dry filter element in engine oil then squeeze out excess oil SPARK PLUGS TECHNICAL MAINTENANCE 13 Spark plug has to b...

Page 13: ...o cool slightly and drain the warm oil Oil will drain faster and easier from a warm engine ATTENTION DANGER MODEL KSB 21 MODEL KSB 21ii S S 1 Place the generator on a flat surface 2 Loosen the screws...

Page 14: ...rrections not authenticated by the seller s seal or illegible inscriptions in the warranty card or tear off coupon no warranty repair is carried out no objections to quality are accepted and the warra...

Page 15: ...DELS KSB 30 MODELS KSB 30ii S S KSB 40 KSB 40iiE S E S MODELS KSB 30 MODELS KSB 30ii S S KSB 40 KSB 40iiE S E S MODEL KSB 21 MODEL KSB 21ii S S MODEL KSB 21 MODEL KSB 21ii S S konner sohnen com 14 1 1...

Page 16: ...SB 40 KSB 40iiE S E S MODELS KSB 30 MODELS KSB 30ii S S KSB 40 KSB 40iiE S E S MODEL KSB 21 MODEL KSB 21ii S S MODEL KSB 21 MODEL KSB 21ii S S 1 1 2 2 3 3 4 4 3 3 1 1 1 1 2 2 2 2 3 3 5 5 4 4 konner so...

Page 17: ......

Page 18: ...de Kundendienst technische Kundendienst technische Fragen und Unterst tzung Fragen und Unterst tzung support dimaxgroup de Garantie Reparatur und Garantie Reparatur und Service Service service dimaxgr...

Reviews: