15. Disposal

15.1

Regulations for Disposal

15.1.1

Germany

It is not allowed to dispose of used electrical equipment as domestic waste.

But please do not dispose of them at official collecting points for recycling either!

All KLING & FREITAG products are plain business-to-business (B2B) products. KLING & FREITAG
products labelled with a waste bin sign have thus to be disposed of by KLING & FREITAG
GmbH alone. Please call KLING & FREITAG at the number stated below if you have a KLING
& FREITAG product to be disposed of. We will offer you a straightforward and professional
disposal with no costs involved.

If there is no waste bin sign on one of your KLING & FREITAG products, because it has been
sold before 24 March 2006, then by law the owner is in charge of the disposal. In this case we
will be happy to assist and offer you proper ways of disposal.

Telephone number to call about the disposal of used KLING & FREITAG products: +49 (0)
511-96 99 7-0

Explanation: With the ElektroG (law relating to electrical and electronic equipment and
appliances) we have complied with the EU-directive on waste electrical and electronic
equipment (WEEE, 2002/96/EC).

From 03/24/2006 onwards KLING & FREITAG GMBH has thus labelled all products mentioned
in the WEEE with a sign with a crossed out waste bin and a white bar below. This sign
indicates that the disposal as domestic waste is prohibited and that the product has been put
into circulation on 03/24/2006 at the earliest.

KLING & FREITAG GMBH has been legally registered as a manufacturer with the German
registration office EAR. Our WEEE registration number is: DE64110372.

For the German Registration office EAR we have accredited that our products are soleB2B
products.

15.1.2

EU, Norway, Iceland, and Liechtenstein

It is not allowed to dispose of used electrical equipment as domestic waste.

From 08/13/2005 onwards KLING & FREITAG GMBH has thus labelled all products for EU-
Member countries as well as Norway, Iceland and Liechtenstein (except Germany) mentioned
in the WEEE with a sign with a crossed out waste bin and a white bar below. This sign
indicates that the disposal on domestic waste is prohibited and that the product has been put
into circulation on 08/13/2005 at the earliest.

Unfortunately the European directive WEEE has been complied with implementing different
national provisions of law throughout all member countries, which makes it impossible for us
to offer consistent solutions for the disposal throughout Europe.

Responsible for complying with these provisions of law is the local distributor (importer) of
each country.

For proper disposal of used products in accordance with these local provisions in the
mentioned countries of the European Union (except Germany) please ask your local dealer or
the local authorities.

15.1.3

All other Countries

For proper disposal of used products in accordance with local provisions in other than the
above mentioned countries please ask your local dealer or the local authorities.

Summary of Contents for NOMOS XLC

Page 1: ...LC Important Information Please Read Before Use KLING FREITAG GmbH Junkersstra e 14 D 30179 Hannover TEL 49 0 511 96 99 70 FAX 49 0 511 67 37 94 www kling freitag de User s Manual Version 4 1 Released...

Page 2: ......

Page 3: ...S XLC combined with other K F tops 8 7 Cardioid Arrays with CD 44 8 7 1 Setup instructions for a cardioid array 10 7 2 LSBlocks for cardioid useNOMOS XLC 11 8 Fuse in the NOMOS XLC 12 8 1 Replacing th...

Page 4: ...use property damage This symbol gives instructions for the proper use of the described products Not following these instructions may cause malfunctions or property damage 1 2 Information about this Us...

Page 5: ...ee this For mobile and fixed installations use only assembly equipment from KLING FREITAG If not otherwise stated in this manual only original KLING FREITAG parts may be used The use of other parts in...

Page 6: ...ossible measures include strapping it to an appropriate base structure or fastening it using safety straps A planned tilt of the loudspeakers ist not permissible In calculations the tilted setup serve...

Page 7: ...high level signals noises which occur when the amplifier is on while equipment is being connected disconnected or switched on Do not install devices in any of the following places where the devices ar...

Page 8: ...op speakers using the controller K F CD 44 To do so select the desired LS blocks for the top in the Controller CD 44 or systemamp TOPAS and combine these with the desired LS block for the NOMOS XLC In...

Page 9: ...9 of 21 simplified miking improved room acoustics with fewer reflections from the rear and side walls or when flown from the ceiling simplified adherence of sound emission limits and therefore less n...

Page 10: ...etup the fronts of the speakers must face the audience When cardioid speakers are put on the floor ensure that there is always a distance of at least 40 cm between and over the speakers We recommend a...

Page 11: ...e available in the K F CD 44 All setups with a cutoff frequency other than 60Hz have a cutoff frequency of 100Hz Operation Mode Chassis LSBlocks NomXLC Cardioid front NomXLC C F rear NomXLC C R Hyperc...

Page 12: ...NOMOS XLC the subwoofers are equipped with fuses at the signal input These fuses reduce the risk of consequential damage resulting from a short circuit i e charred cables connectors fire damage 8 1 R...

Page 13: ...ersion 4 1 Page 13 of 21 9 Connection The operating safety and the highest possible performance is only guaranteed in conjunction with the K F Topas or K F SystemRack 9 1 Terminal assignment 2 2 1 1 2...

Page 14: ...User s manual K F NOMOS XLC KLING FREITAG GMBH 2014 Version 4 1 Page 14 of 21 9 2 Cabling a K F System Rack...

Page 15: ...MOS XLC The following connecting diagram shows an example with the K F CD 44 Routing 1 in 4 out A maximum of 3 NOMOS XLC subwoofers can be driven by one K F SystemRack If you want to use 3 NOMOS XLC s...

Page 16: ...recommend using the optional soft cover 11 Technical Specifications Design Bass reflex system Operations via K F SystemRack Crossover frequencies 2 Way Mode 60 Hz 100Hz 60 Hz Lower cut off frequency 3...

Page 17: ...profiles for optional transport cover ball proof steel grilles with exchangeable black acoustic foams behind grilles Dimensions W x H x D 1200 x 600 x 903 with castors Weight 95 0 kg Transport Cover...

Page 18: ...80 Hz 100 Hz 125 Hz 40 Hz 50 Hz 63 Hz 0 30 330 300 270 240 210 180 150 120 90 60 0 30 330 300 270 240 210 180 150 120 90 60 12 dB 12 dB 24 dB 24 dB Hypercardioid 80 Hz 100 Hz 125 Hz 40 Hz 50 Hz 63 Hz...

Page 19: ...User s manual K F NOMOS XLC KLING FREITAG GMBH 2014 Version 4 1 Page 19 of 21 13 Dimensions NOMOS XLC...

Page 20: ...NG FREITAG GMBH 2014 Version 4 1 Page 20 of 21 14 Accessories Protective Cover NOMOS XLC Transport Cover NOMOS XLC K F BOB C Speaker signal distributor 1 x 8 pin into 3 x 4 pin For operations of 3 x N...

Page 21: ...stic waste is prohibited and that the product has been put into circulation on 03 24 2006 at the earliest KLING FREITAG GMBH has been legally registered as a manufacturer with the German registration...

Reviews: