Combo — Manual
3.2
Toggle QNH hPa – inHg
2. Turn the knob on Indu Combo to indicate 1020 hPa (30.12
inHg) and wait for about 3 seconds for a short cyan line to
appear on the top of LCD display.
3. Quickly turn the knob to indicate 999 hPa (29.50 inHg). A
moment later a longer cyan line appears on the top. You must
reach 999 hPa before cyan line disappears.
4. Turn the knob to select 1013 hPa (29.91 inHg) and wait for a
moment. Again, you have to reach this value before cyan line
disappears.
5. Now a full cyan line appears and the LCD display is slightly
altered. It shows the offset and the altitude. Turn the knob
until Indu Combo shows the same altitude as the reference
altimeter. Wait for cyan line to disappear.
This completes the sensor offset procedure.
3.2
Toggle QNH hPa – inHg
1020
→
1025
→
1013 for hPa or 30
.
12
→
30
.
27
→
29
.
91 for inHg.
Part of the LCD display is also a QNH value. This value can be
shown in hPa or in inHg units. You can change the units using next
procedure:
1. Turn the knob until it shows 1020 hPa (30.12 inHg) and wait
for about three seconds for a short cyan line to appear on top
of LCD display.
2. Quickly turn the knob to indicate 1025 hPa (30.27 inHg). A
moment later a longer cyan line appears.