Emsis — Manual
6.1
Installation to the Instrument Panel
on a thick piece of paper. After printing take precise ruler or mea-
suring tape and make sure that printed sizes are correct. Drill the
mounting holes in the panel using 4.5 mm drill.
If you do not want to cut the panel yourself, you may consider to
machine cut the opening in a local workshop using CNC equipment
(a laser cutting machine is typically used). After cutting make sure,
that Emsis fits into the new opening. You can powder paint the
panel using non-reflective dark paint. This makes excellent results in
practice.
The Emsis unit is mounted from the back. Position Emsis unit in
the instrument panel and use the screws to fix it in place.
6.1.1
Emsis Back Panel Connectors and Cable Clearance
Emsis units are divided into two main groups (according to the back
panel), Emsis with AHRS unit built-in and all the others. Here is a
brief description of individual connectors from Figure 28:
Figure 28:
Emsis unit with AHRS built-in (left), Emsis slave unit
(right). Both versions are available in 80 mm and 3.5”
screens
52
©
Kanardia
2021