TECHNICAL DESCRIPTION
ULTRAFLOW
®
54 and 34
5512-385 GB/02.2014/Rev. H1
49
9.3
Connection
Connection via three-wire cable from ULTRALFOW
®
Yellow
Signal
Red
Supply
Blue
Ground
Supply
3.6 VDC ± 0.1 VDC
Output when using Pulse Transmitter/Pulse Divider with galvanically separated output module (Y=2)
Type
Open collector. Can be connected as two-wire or three-wire via the built-in pull-up resistance
of 56.2 k
Ω.
Module Y=2
OC and OD
(OB) Kam
Max input voltage 6 V
30 V
Max input current
0,1 mA
12 mA
ON condition
U
≤
0,3 V @ 0,1 mA
U
CE
≤
2,5 V @ 12 mA
OFF condition
R
≥
6 M
Ω
R
≥
6 M
Ω
Table 24