TECHNICAL DESCRIPTION
ULTRAFLOW
®
54 DN150-250
5512-876 GB/04-2012/Rev. F1
16
6
Pressure loss
Pressure loss in a flow sensor is stated as max. pressure loss at q
p
.
According to EN 1434 max. pressure loss must not exceed 0.25 bar unless the energy meter includes a flow
controller or functions as pressure reducing equipment.
The pressure loss in a meter increases with the square of the flow and can be stated as:
p
kv
Q
∆
×
=
where:
Q = volume flow rate [m³/h]
kv = volume flow rate at 1 bar pressure loss
∆
p = pressure loss [bar]
Nom. flow q
p
Nom. diameter
Q at 0.25 bar
[m³/h]
[mm]
[m³/h]
A
150 & 250
DN150
1060
530
B
400
DN150
2000
1000
C
400 & 600
DN200 & DN250
4040
2020
D
1000
DN250
8160
4080
Graph
kv
Table 9. Pressure loss table.
∆
∆
∆
∆
p ULTRAFLOW
®
54 DN150-250
0,01
0,1
1
100
1000
10000
Flow [m³/h]
∆∆∆∆
p
[
b
a
r]
A
B
C
D
Diagram 1. Pressure loss graphs.