8.1.4 Wall exterior
Mount READy MTU as high as possible. The MTU should be mounted at or above ground level.
Always install READy MTU in the protection cover (accessory) when the device is installed in sun-exposed areas.
Mount READy MTU at least 6 inches away from any metal objects, including pipes, conduit, and downspouts.
When mounting multiple MTUs in the same location, leave at least 4 inches between the MTUs if mounting side
by side and at least 3 inches between MTUs if mounting one above another.
Do not mount READy MTU so that it is transmitting towards a nearby building or fence.
Do not mount READy MTU directly under AC power or telecommunications wires.
Finish the field configuration of READy MTU before installing it in the protection cover.
Use the protection cover in sun-exposed areas. When installed in areas without sun exposure, the wall/pit bracket can
potentially be used.