6.  Retrofitting modules

Both top modules and base modules for MULTICAL

®

 61 can be supplied separately 

for retrofitting. The modules are configured and ready for installation from the 
factory. Some of the modules require individual configuration after installation, 
which is possible by means of METERTOOL.

Top module

Possible configuration after installation

RTC (Real Time Clock)

1

Clock adjustment.

RTC + data hourly data logger

5

Clock adjustment.

RTC + M-Bus

7

Clock adjustment.
Primary and secondary M-Bus addresses 
can be changed via METERTOOL or M-Bus. 
Furthermore, monthly logger data can be 
selected instead of yearly logger data via 
M-bus.

RTC + 2 pulse outputs for CE and CV + hourly 
data logger

8

Clock adjustment. Configuration of pulse 
outputs. (Configured from the factory 
according to customer requirements)

RTC + 2 pulse outputs for CE and CV + prog. 
data logger

B

Clock adjustment.
Configuration of pulse outputs.

Base module
Data + pulse inputs

10

Pulse values of VA and VB are changed via 
METERTOOL.

M-Bus + pulse inputs 

20

Pulse values of VA and VB are changed via 
METERTOOL.
Primary and secondary M-Bus addresses 
can be changed via METERTOOL or M-Bus. 
Furthermore, monthly logger data can be 
selected instead of yearly logger data via 
M-bus.

RadioRouter  + pulse inputs

21

Pulse values of VA and VB are changed via 
METERTOOL.

Prog. data RTC + 4…20 mA  
pulse inputs

22

Clock adjustment.
Pulse values of VA and VB are changed via 
METERTOOL.

0/4…20 mA outputs

23

Config data must be programmed into the 
calculator by means of METERTOOL when 
retrofitting. Furthermore, all parameters can 
be changed via METERTOOL.

LonWorks, FTT-10A + pulse inputs

24

Pulse values of VA and VB are changed via 
METERTOOL. All other configurations are 
made via LonWorks.

Radio + pulse inputs 
(integral antenna)

25

Pulse values of VA and VB are changed via 
METERTOOL.

Radio + pulse inputs 
(connection for external antenna)

26

Pulse values of VA and VB are changed via 
METERTOOL.

Summary of Contents for MULTICAL 61

Page 1: ...Installation and User Guide for MULTICAL 61 Cold Water Meter www kamstrup com...

Page 2: ...170K Temperaturf lers t 10 C 150 C 3K 140K Flowm ler 15 C 130 C Mekanisk milj M1 fast installation med minimal vibration Elektromagnetisk milj E1 og E2 bolig let industri og industri M lerens signalka...

Page 3: ...Kamstrup A S Industrivej 28 Stilling DK 8660 Skanderborg TEL 45 89 93 10 00 FAX 45 89 93 10 01 info kamstrup com www kamstrup com MULTICAL 61 Cold Water Meter English I N S T A L L A T I O N...

Page 4: ...wer supplies can be added The utility can replace communication module and battery If greater distance is required up to 10 m between flow sensor and display unit a PULSE TRANSMITTER type number 66 99...

Page 5: ...t proper tightening of the sealing surface and that PN10 glands are used PN16 glands gaskets can be used When the installation has been completed water flow can be turned on The valve on the inlet sid...

Page 6: ...ng is mounted on the flow sensor type no 3026 252 is ordered separately The cable must be mounted minimum 25 cm from other electric installations Do not forget to seal the calculator Important ULTRAFL...

Page 7: ...lifetime of the battery approx 3 65 V Therefore it is not possible to determine the remaining capacity by measuring the voltage The battery cannot and must not be charged and must not be short circui...

Page 8: ...RS232 level requires connection of data cable 66 99 106 D Sub 9F or 66 99 098 USB with the following connections 62 Brown DAT 63 White REQ 64 Green GND The pulse inputs can be used for connection of...

Page 9: ...mains supply 5 1 4 Prog data logger RTC 4 20 mA inputs pulse inputs 67 00 22 The module has connection possibility for two pressure transmitters on terminals 57 58 and 59 and can be adjusted for curre...

Page 10: ...nals are not used in this module Type 67 05 RTC data output hourly data logger The module has a galvanically separated data port which functions with the KMP protocol The data output can be used for e...

Page 11: ...e for volume pulses for water meters The pulse resolution follows the display fixed in the CCC code E g CCC 419 Q3 1 6 m3 h 1 pulse 0 01m3 The pulse outputs are optoisolated and withstand 30 VDC and 1...

Page 12: ...k adjustment Configuration of pulse outputs Base module Data pulse inputs 10 Pulse values of VA and VB are changed via METERTOOL M Bus pulse inputs 20 Pulse values of VA and VB are changed via METERTO...

Page 13: ...ription Response time 0 No irregularities 1 Supply voltage has been interrupted 16 Flow meter V1 communication error signal too weak or wrong flow direction After reset e g cover off and on as well as...

Page 14: ...hange battery or check mains supply No display function empty display Power supply missing Change battery or check mains supply Is there 3 6 VDC on terminals 60 and 61 If info 1 Supply voltage has bee...

Page 15: ...by current time Target date displayed as month and day In this example 1 June The calculator s serial number The program number of the calculator Followed by configuration codes DDD EE and FFF GG M N...

Page 16: ...rtant functions If there is a serious error in measuring system or installation a flashing info will appear in the display until the error has been corrected The Info field flashes as long as the erro...

Reviews: