TECHNICAL DESCRIPTION
MULTICAL
®
41
5512-313 GB/01.2010/Rev. C1
13
3.3.2
>E< Configuration is not used for MULTICAL
®
41
Set default at:
0
3.3.3 >FF< Input a, >GG< Input b, pulse separation (f
≤
0.5 Hz)
Input a
Terminal 65-66
Input b
Terminal 67-68
FF
Max. input
GG
Max. input
Pre-counter l/pulse
Measuring unit and decimal
point
00
OFF
00
OFF
-
- -
-
01
50 m³/h
01
50 m³/h
1
100
m³a – m³b
000000.0
02
25 m³/h
02
25 m³/h
2
50
m³a – m³b
000000.0
03
12 m³/h
03
12 m³/h
4
25
m³a – m³b
000000.0
04
5 m³/h
04
5 m³/h
10
10
m³a – m³b
000000.0
05
2.5 m³/h
05
2.5 m³/h
20
5.0
m³a – m³b
000000.0
06
1 m³/h
06
1 m³/h
40
2.5
m³a – m³b
000000.0
07
0.5 m³/h
07
0.5 m³/h
100
1.0
m³a – m³b
000000.0
24
5 m³/h
24
5 m³/h
1
10
m³a – m³b
00000.00
25
2.5 m³/h
25
2.5 m³/h
2
5.0
m³a – m³b
00000.00
26
1 m³/h
26
1 m³/h
4
2.5
m³a – m³b
00000.00
27
0.5 m³/h
27
0.5 m³/h
10
1.0
m³a – m³b
00000.00
40
500 m³/h
40
500 m³/h
1
1000
m³a – m³b
0000000
NB: Electricity meters cannot be connected as 1 sec. pulse and pause are required.
3.4
DATA
Automatic
To be stated when ordering Default
Serial no. (S/N) and year E.g.
2500000/2005
-
-
Customer no.
-
Up to 11 digits
Customer no. = S/N
Target date
-
MM=1-12 and DD=1-28
06.01 (1 June)
TL2
- - 0
TL3
- - 0
Peak average time
-
1…120 min.
60 min.
Date/time YY.MM.DD/hh.mm.ss
-
-
Telephone number #1
-
Max. 12
-
Telephone number #2
-
Max. 12
-
3.5
Other functions
When making orders in BOS, select ”Locked M-Bus adr.” and all meters in one order are made with the same
customer number, e.g. 001. However, this requires customer label 2001-500 or higher.