1. General information
Please read these instructions before installing the heat meter.
Kamstrup’s guarantee obligations do not apply in case of incorrect
installation.
Please note the following installation requirements:
Max. inlet pressure for meters with screw-joints is 16 bar.
1.1 MID designations
The meter is approved according to MID (OIML R49).
Rated operation conditions/measuring ranges:
Temperature of medium in flow sensor: 0.1°C…30°C
Mechanical environment: M1 (fixed installation with minimum
vibration)
Electromagnetic environment: E1 (Domestic and light industrial).
Signal cables from the meter must be separated by at least 25 cm
distance to other installations.
Climatic environment: The installation shall be made in
non-condensing environments and in closed location (indoor).
The ambient temperature must be within 5…55°C.
Maintenance and repair: The water supplier is allowed to change
communication module and battery. The flow part must never be
separated from the calculator. All repairs require a following
re-verification on an accredited laboratory.
Battery for replacement: Kamstrup type 66-00-200-100.