Summary of Contents for MULTICAL 402

Page 1: ...rkshire RG6 4UT UK Tel 44 0 118 9311188 Email info able co uk Aberdeen Office Unit 6 Airside Business Park Kirkhill Industrial Estate Dyce Aberdeen AB21 0GT UK Tel 44 0 1224 725999 Email ab able co uk...

Page 2: ...tlet pipes register the cooling i e the difference between input and output temperatures MULTICAL 402 calculates consumed energy based on volume of district heating water and cooling Readings When the...

Page 3: ...MULTICAL 402 English U S E R S G U I D E Kamstrup A S Industrivej 28 Stilling DK 8660 Skanderborg Tel 45 89 93 10 00 Fax 45 89 93 10 01 info kamstrup com www kamstrup com...

Page 4: ...ce to other installations Climatic environment Must be installed in environments with non condensing humidity as well as in closed locations indoors The ambient temperature must be within 5 55 C Maint...

Page 5: ...6 2 Mains modules 13 7 Testing the function 14 8 Electrical connection 14 9 Plug in modules 15 9 1 Pulse inputs 15 9 2 Pulse outputs 15 9 3 Data pulse inputs type 402 0 10 16 9 4 Data pulse outputs t...

Page 6: ...e ters is recommended and the calculator should be wall mounted 2 Mounting of temperature sensors The temperature sensors used to measure inlet and outlet temperatures are a matched sensor set that mu...

Page 7: ...he middle of the water flow Temperature sensors should be inserted to the bottom of the pockets If a short response time is required non hardening heat conducting paste can be used Push the plastic sl...

Page 8: ...ads on the meter case Fasten the brass unions of the sensors lightly approx 4 Nm using a 12 mm face wrench and seal the sensors with seal and locking wire 3 Information codes INFO MULTICAL 402 constan...

Page 9: ...range info code 12 is displayed 4 Mounting of flow sensor Prior to installation of the flow sensor the system should be flushed and protection plugs plastic diaphragms removed from the flow sensor Cor...

Page 10: ...hall be checked that 10 mm thread run out is sufficient See the figure below Straight inlet MULTICAL 402 requires neither straight inlet nor straight outlet to meet the Measuring Instruments Directive...

Page 11: ...d flow sensor position C Unacceptable position due to risk of air build up D Acceptable in closed systems Unacceptable position in open sys tems due to risk of air build up in the system E A flow sens...

Page 12: ...MULTICAL 402 can be mounted vertically horizontally or at an angle MULTICAL 402 must not be mounted with the plastic box pointing upwards MULTICAL 402 may be turned up to max 45 and downwards for max...

Page 13: ...is installed in moist environments it must be turned 45 relative to the pipe axis as shown in the drawing below Flow from the left Flow from the right Flow from the left Flow from the right 45 If ther...

Page 14: ...applications we recommend wall mounting of the calculator Furthermore MULTICAL 402 must be the condensation pro tected version 5 2 Wall mounting If minimum installation depth G and G1 is re quired th...

Page 15: ...of the battery approx 3 65 V Therefore it is not possible to de termine the remaining capacity of the battery by measuring the voltage The battery cannot and must not be charged and must not be short...

Page 16: ...ly mounted Open thermoregulators and cocks to establish water flow through the heating system Activate the top key on MULTICAL 402 and check that the displayed values for temperatures and water flow a...

Page 17: ...VB After delivery the configuration of VA and VB config FF and GG can be changed by means of the PC program METERTOOL 65 VA Pulse input 66 67 VB Pulse input 68 9 2 Pulse outputs Pulse outputs for ener...

Page 18: ...tputs type 402 0 11 The data terminals are used for connection of e g a PC The signal is passive and galvani cally separated by means of optocoup lers Conversion into RS232 level requires connec tion...

Page 19: ...mportant The module is powered by the connected master 9 7 M Bus module with MULTICAL III data package pulse inputs type 402 0 29 The M Bus module 402029 comprises the same data packet as M Bus module...

Page 20: ...quency band in the 434 MHz area The radio module comes fitted with internal antenna 9 10 Radio pulse inputs type 402 0 42 and 402 0 44 The radio modules have been optimized to form part of a Kamstrup...

Page 21: ...or the hand held reading systems in the same frequency area The radio module comes fitted with internal antenna as well as connection for external antenna and two pulse outputs Mounting an external an...

Page 22: ...a 5550 1029 402 0 35 Wireless M Bus C1 alternative registers encrypted 868 MHz internal and external antenna pulse inputs 5550 1203 402 0 37 Wireless M Bus EU 868 MHz Mode T1 Common key internal anten...

Page 23: ...any keys 4 Keep pressing the main key while the supply is connected to the meter connecting the supply plug to the meter until no lines are shown in the display 5 The setup menu is now active Having...

Page 24: ...first digit on the right by means of the main key When the value of the reading has been changed you quit by pressing the main key continuously for 5 6 seconds Now check whether the value is valid for...

Page 25: ...23...

Page 26: ...5512772_C4_GB_12 2013...

Page 27: ...on last year s target date Followed by monthly counts Current inlet temperature Press to view yearly and monthly average values Current outlet temperature Press to view yearly and monthly average valu...

Page 28: ...number The calculator s program number In this example Flow meter in outlet pipe MWh and 100 imp l Followed by the calculator s configuration number and software edition Display test DDD 213 DDD 212 A...