IP201
5 Installation
When supply has been established, the Err and Wink diodes are lit to indicate that the module is
switched on. The Link diode lights/flashes if the RJ45 cable is mounted (communication on the
network is indicated by flashes).
During start-up, the Err and Wink diodes are used for controlling the state of the module:
1
Err and Wink emit light constantly: The module has just started.
2
The Wink diode turns off when the module has established connection to the network (valid IP).
3
The Err diode starts flashing when the host is recognised (meter or concentrator have been
detected).
4
The Err diode turns off when the module has been registered by the collecting server.
If the module cannot connect to the meter and/or server, IP201 will restart.
Start-up
ACT/LINK
WINK
ERR
Power UP
Off
On
On
LAN connection
On/flash
-
-
~3 sec (depending on DHCP srv), ~0 sec if static IP is used.
Valid IP
On/flash
Off
On
15-20 sec.
Host recognised (meter/conc)
On/flash
Off
Flash
20 sec (depending on AMR system).
Ack from server
On/flash
Off
Off
Ethernet connection
ACT/LINK
WINK
ERR
No Ethernet
Off
–
–
LAN OK – idle
On
–
–
LAN OK –data activity
Flash
–
–