flowIQ® 3100 TECHNICAL DESCRIPTION
13
Ka st up A/S • Te h i al Des iptio •
5512-1242_D1_GB
•
09.2016
5
Confi
guration
Configuration
KK
LLL
MMM
N
P
R
S
T
□□
□□□
□□□
□
□
□
□
□
Target date
01
Average time of max. values
2 minutes
…
i .
002
Customer label 2005-MMM
MMM
Leakage message limit
OFF
0
Flow continuously > 0.5% of Q
3
1
Flow continuously > 1.0% of Q
3
2
Flow continuously > 2.0% of Q
3
3
Pipe burst limit
OFF
0
Flow > 5 % of Q
3
for 30 minutes
1
Flow > 10 % of Q
3
for 30 minutes
2
Flow > 20 % of Q
3
for 30 minutes
3
Optional register in data logger
* ‘e o
e ded for Dri e
-
** ‘e o
e ded for Fi ed et ork
Wired M-Bus datagram
0
Monthly target volume
1
Max. flow during last month
2
Monthly target volume/
Min.temp.water, daily
/Time weighted average temp. meter, daily
**
3
Monthly max. flow/Average temp.water,daily/Time weighted aver. temp. meter,daily
**
4
Monthly target volume /
Min. water temp. monthly
/ Min. temp. meter,latest month
*
5
Monthly target volume/
Min. water temp., monthly
/Max. temp. meter, latest month
*
7
Daily max. flow /
Min.temp.water, daily
/ Time weighted average temp. meter, daily
**
9
1)
Measuring the water temp. is only valid for
meter sizes 1.6, 2.5 and 4.0 m
3
/h
Display resolution
00001 m³
0
00000.1 m³
1
00000.01 m³
2
00000.001 m³
3
Encryption level
No encryption
0
Utility encryption (only available for selected markets)
2
Encryption with separately forwarded key
3
Unless otherwise stated in the order,
Kamstrup supplies the following:
01
002 000
2
3
5
3
3