background image

WKD

Assembly instructions

EN

Assembly instructions

3

SAP 1423948 03/22

1

Overview

1

1

2

2

3

3

4

4

5

5

WKD at a glance

1

Ceiling bracket

2

Connection fittings

3

Junction box

4

Front panel

5

Motor adjustment connection

2

Safety

This section provides an overview of all important safety aspects to ensure optimum protection
of personnel as well as safe and trouble-free operation. In addition to the safety instructions in
these operating instructions, the valid safety, accident prevention and environmental protection
regulations must be observed for the area of use of the unit. It is the duty of the operator to en-
sure that instructions relating to maintenance (e.g. relating to hygiene) are complied with.

2.1

Correct use

Intended use of the unit also includes adherence to these instructions.

Any use beyond or other than the stated intended use is considered as misuse.

Any change to the unit or use of non-original spare parts will cause the expiry of the warranty
and the manufacturer’s liability.

2.2

Limits of operation and use

IMPORTANT NOTE!
Warning of misuse!

In the event of misuse, as itemised below, there is a danger of limited or failing
operation of the unit. Ensure that the airflow can circulate freely.

Never operate the unit in humid areas, such as swimming pools, wet areas
etc.
Never operate the unit in rooms with an explosive atmosphere.
Never operate the unit in aggressive or corrosive atmospheres (e.g. sea air).

2.3

Personnel requirements - Qualifications

Expertise

The installation of this product requires specialist knowledge of heating, cooling, ventilation, in-
stallation and electrical engineering.

Damage caused by improper installation is the responsibility of the operator or installer. The in-
staller of these units should have adequate knowledge of the following gained from specialist
professional training

Safety and accident prevention regulations
Country-specific guidelines and recognised technical regulations, i.e. Association of German
Electricians (VDE) regulations, DIN and EN standards.
VDI 6022; maintenance personnel must be trained to Category B (possibly Category C) to
comply with hygiene requirements (as required).

2.4

Personal Protective Equipment

Personal protective equipment is used to protect people from impaired safety and health when
working with the unit. The applicable accident prevention regulations at the place of use apply
in all cases.

3

Transport, storage and packaging

3.1

General transport instructions

Check on delivery for completeness and transport damage.

Proceed as follows in the event of visible damage:

Do not accept delivery or only accept with reservations.
Record any transport damage on the transportation documents or on the transport company's
delivery note.
Submit a complaint to the freight forwarder.

IMPORTANT NOTE!

Warranty claims can only be made within the applicable period for complaints.
(More information is available in the 

T&Cs

 on the Kampmann website)

4

Technical data

Electrical data for damper drive CM24-SX-L

Nominal voltage [V]

24

Mains voltage frequency [Hz]

50/60

Operating range [V]

AC 19.2 ... 28.8 V / DC 19.2 ... 28.8 V

Operating power consumption [W]

1

Idle power consumption [W]

0.5

Dimensioning power consumption [VA]

1.5

Cable colours:

1 = black
2 = red
3 = white
4 = orange

Circuit diagram AC/DC 24 V, continuous

Kampmann GmbH & Co. KG

Friedrich-Ebert-Str. 128-130

49811 Lingen (Ems)

T: +49591/7108 0

E: [email protected]

www.kampmann.de

Summary of Contents for WKD CM24-SX-L

Page 1: ...ng L ftung Instal lation und Elektrotechnik voraus Sch den die aus einer unsachgem en Montage entstehen hat der Betreiber oder Installateur zu tragen Der Installateur dieses Ger ts soll aufgrund seine...

Page 2: ...erkzeug an der Decke befestigen 3 Anschlusskasten gegen Herunterfallen sichern Winkel beidseitig mit Kontermuttern si chern und waagerecht ausrichten 4 Frontplatte anschrauben 5 Motorverstellung verka...

Page 3: ...electrical engineering Damage caused by improper installation is the responsibility of the operator or installer The in staller of these units should have adequate knowledge of the following gained f...

Page 4: ...tool to fix the ceiling bracket not supplied to the ceiling 3 Secure the plenum box to prevent it from falling Secure both sides of the bracket with lock nuts and align horizontally 4 Screw on front...

Page 5: ...du refroidissement de l a ration de l installation et de l lectrotechnique L exploitant ou l installateur est seul responsable des dommages r sultant d un montage non conforme En raison de sa formatio...

Page 6: ...l appropri 3 S curiser le caisson de jonction pour l emp cher de tomber Placer les querres horizon talement et les fixer de chaque c t l aide de contre crous 4 Visser la plaque frontale 5 C bler le d...

Page 7: ...ktrotechniek vereist De exploitant of installateur is verantwoordelijk voor schade die door een ondeskundige monta ge worden veroorzaakt De installateur van dit apparaat moet op basis van zijn vakople...

Page 8: ...reedschap aan het plafond bevestigen 3 Aansluitkast tegen omlaag vallen beveiligen Hoekstuk aan beide zijden met contra moeren borgen en horizontaal uitlijnen 4 Voorplaat vastschroeven 5 Kabels van de...

Page 9: ...lettrotecnica I danni riconducibili a un montaggio improprio sono a carico del gestore o dell installatore L in stallatore di questo apparecchio deve possedere conoscenze sufficienti maturate nel cors...

Page 10: ...li adeguati 3 Fissare la scatola dei collegamenti in modo che non cada Fissare l angolare su entram bi i lati con i controdadi e allinearlo in orizzontale 4 Avvitare la piastra frontale 5 Cablare la r...

Page 11: ...rzewania ch odze nia wentylacji instalacji i elektrotechniki Odpowiedzialno za szkody wynikaj ce z niepoprawnie wykonanego monta u ponosi u ytkow nik lub instalator Instalator niniejszego urz dzenia p...

Page 12: ...odpo wiedniego narz dzia 3 Skrzynk przy czeniow zabezpieczy przed upadkiem K townik zabezpieczy z obu stron nakr tkami zabezpieczaj cymi i wyr wna w poziomie 4 Przykr ci p yt przedni 5 Pod czy przewo...

Page 13: ...13 1 2 3 4...

Page 14: ...14...

Page 15: ...15...

Page 16: ...16...

Reviews: