Kampmann KSH Assembly, Installation And Operating Instructions Download Page 5

KSH

Luftdurchlässe

Assembly, installation and operating instructions

5

2

Safety

This section provides an overview of all important safety aspects to ensure optimum protection of personnel as well as safe
and trouble-free operation. In addition to the safety instructions in these operating instructions, the valid safety, accident pre-
vention and environmental protection regulations must be observed for the area of use of the unit. It is the duty of the oper-
ator to ensure that instructions relating to maintenance (e.g. relating to hygiene) are complied with.

2.1

Correct use

Combined diffusers are designed to supply and distribute preconditions air into air conditioned sealed indoor areas with am-
bient temperatures of between 0 – 50°C and a relative air humidity of up to a maximum of 90%. The operating limits and
limits of use described in 

Chapter 2.2 [

}

 5]

 must be observed.

Intended use of the unit also includes adherence to these instructions.

Information in accordance with EN60335-1

This unit can be used by children aged 8 years or more and also by people with reduced physical, sensory or mental cap-
abilities or a lack of experience and knowledge, if they are supervised or have been instructed in the safe use of the unit
and the resulting dangers. Do not allow children to play with the unit. Do not allow children to clean and maintain the
unit without supervision.
This unit is not intended for permanent connection to the drinking water supply system.
This unit is intended for being accessible to the general public.

Any use beyond or other than the stated intended use is considered as misuse.

Any change to the unit or use of non-original spare parts will cause the expiry of the warranty and the manufacturer’s liabil-
ity.

2.2

Limits of operation and use

Variable

Value

Unit

Temperature range

0 – 50

°C

Max. relative air humidity

90

%

IMPORTANT NOTE!

Warning of misuse!

In the event of misuse, as itemised below, there is a danger of limited or failing operation of the unit. En-
sure that the airflow can circulate freely.

Never operate the unit in humid areas, such as swimming pools, wet areas etc.
Never operate the unit in rooms with an explosive atmosphere.
Never operate the unit in aggressive or corrosive atmospheres (e.g. sea air).

Summary of Contents for KSH

Page 1: ...KSH Assembly installation and operating instructions Keep these instructions in a safe place for future use Issue01 21EN SAP No 1363595...

Page 2: ......

Page 3: ...a 9 5 Construction and function 10 5 1 Overview 10 5 2 Brief description 10 5 3 Dimensions Nominal lengths 11 6 Installation and wiring 12 6 1 Requirements governing the installation site 12 6 2 Insta...

Page 4: ...tained in this manual In addition all local occupational health and safety at work regulations apply as do general safety provisions governing the use of the equipment Illustrations in this guide are...

Page 5: ...ren aged 8 years or more and also by people with reduced physical sensory or mental cap abilities or a lack of experience and knowledge if they are supervised or have been instructed in the safe use o...

Page 6: ...comply with the applicable laws standards provisions and reg ulations in the respective country and the current state of the art Specialist knowledge The installation of this product requires speciali...

Page 7: ...website IMPORTANT NOTE 2 people are needed to transport the unit Wear personal protective clothing when transporting the unit Only lift the unit on both sides and not by the pipes valves IMPORTANT NOT...

Page 8: ...xpose to aggressive media Protect from direct sunlight Avoid mechanical vibrations and shocks IMPORTANT NOTE Under certain circumstances packages can carry storage instructions that exceed the require...

Page 9: ...total of supply air and exhaust air dB A Pressure loss on supply air side p Pa 2 800 64 64 26 16 80 80 32 24 96 96 37 33 112 112 41 45 128 128 44 58 1000 80 80 27 16 100 100 33 24 120 120 38 33 140 1...

Page 10: ...front 2 slot version 5 Acoustic insulation backing building material class B1 6 Eccentric roller 5 2 Brief description The KSH is a combined diffuser for use in and behind drywalls The opening combine...

Page 11: ...5 115 115 115 E diameter of spigot 98 98 98 98 98 F width of rear side 100 100 100 100 100 Tab 2 Dimensions of available nominal lengths number of slots 2 Number of slots 3 Nominal length 500 Nominal...

Page 12: ...to take the weight of the unit Make sure that the ceiling is sufficiently load bearing to take the weight of the unit Technical data 9 Make sure that the unit is securely suspended standing Ensure th...

Page 13: ...the large drill hole on the dry wall Mark points for drill holes on the KSH Fig 5 Drilling holes Use a steel drill 4 mm to drill the marked holes Fig 6 Connecting the bracket to the housing Connect t...

Page 14: ...of the diffuser also needs to be fitted in such a way that the adhesive label points upwards This prevents the supply air from blowing downwards Alternative installation situation KSH rotated Standard...

Page 15: ...ly installation and operating instructions 15 6 2 5 Adjusting the optional volumetric flow limiter The optional volumetric flow limiter can be manually adjusted by turning as shown below using the sca...

Page 16: ...t so that the unit can function safely and properly Structural tests Check that the unit is securely standing and fixed Check the horizontal installation suspension of the unit Check whether all compo...

Page 17: ...with air internal surfaces of the unit outlet elements etc for dirt or deposits dur ing maintenance and use a commercially available product to remove Fig 11 Loosen screws on the left and right Unscr...

Page 18: ...g Remove the acoustic insulation backing 2 pieces and remove any dirt if re quired Fig 15 Cleaning the diffusers Carefully use a damp cloth to clean the diffusers 8 2 Cleaning the volumetric flow limi...

Page 19: ...Assembly installation and operating instructions 19 Table Tab 1 Technical data KSH 9 Tab 2 Dimensions of available nominal lengths number of slots 2 11 Tab 3 Dimensions of available nominal lengths nu...

Page 20: ...produkte luftdurch laesse ksh Country Contact Great Britain Kampmann UK Ltd Dial House Govett Avenue Shepperton Middlesex TW17 8AG T 44 1932 228592 F 44 1932 228949 E info kampmann co uk W Kampmann co...

Reviews: