Kamoer KSP-F01A-DC User Manual Download Page 12

KSP

F01A

 

Dosing

 

Pump

 

User

 

Manual

 

 

12

7

 

Application

 

For

 

better

 

understanding

 

customers’

 

needs

 

and

 

testing

 

our

 

dosing

 

pump’s

 

performance,

 

our

 

company

 

resorts

 

to

 

senior

 

coral

 

experts

 

to

 

take

 

care

 

of

 

our

 

coral

 

tanks

 

by

 

using

 

KSP

F01A

 

dosing

 

pump

 

to

 

add

 

nutrient

 

solution

 

(Ca,

 

Mg,

 

KH

 

etc.)

 

 

Tank

 

volume:

 

360L

 

Creature:

 

SPS

 

6

LPS

 

5

Fish

 

4

Other

 

8

 

Dosing

 

solution

Calcium,

 

Magnesium,

 

KH

 

Dosing

 

amount

 

20ml

take

 

Cal

 

as

 

an

 

example

 

Dosing

 

times

4

 

times

 

/day

 

 

How

 

to

 

use

 

1.

 

Connect

 

the

 

tubing

 

2.

 

Empty

 

the

 

tubing

 

(manual

 

operation

 

emptying,

 

while

 

adjusting

 

the

 

knob

 

to

 

the

 

appropriate

 

flow

 

rate);

 

3.

 

Calibrate

 

flow

 

rate;

 

4.

 

Need

 

to

 

add

 

20ml

 

per

 

day,

 

drop

 

4

 

times;

 

each

 

drop

 

5ml,

 

interval

 

6

 

hours;

 

 
 

 

 
 

5.

 

Press

 

“Auto”

 

to

 

start.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for KSP-F01A-DC

Page 1: ...KSP F01A Dosing Pump User Manual 1 KSP F01A Dosing Pump User Manual Version A 3 Kamoer Fluid Tech Shanghai Co Ltd www kamoer com...

Page 2: ...son 3 Use of non produced material by our company i e pump tube 4 Damage by disaster 5 Improper maintenance causing damage 6 Use of reagent or sample causing corrosion 7 Damage by accident or over loa...

Page 3: ...re change or mechanical wear may increase the volume error 2 Defect and anomalous situation You must stop any operation immediately if the equipment is damaged The equipment may be damaged when the fo...

Page 4: ...be set support cycle run support time span run Support flow rate calibration Support multiple machine use in a series with expansion cable 1 2 Parts Name 1 Button 2 LCD display 3 LCD protective scree...

Page 5: ...d of start time of period page To the field of end time of period page Clock the field of clock page Note 1 The lower left corner of the lock icon shows that the pump is running at this time it cannot...

Page 6: ...99 hours 59 minutes 59 seconds Note In the idle state long press Calibration for 5 seconds switch volume running mode and time running mode 2 2 Delay interface The waiting time between each running th...

Page 7: ...mp User Manual 7 2 5 Calibration interface The countdown page The high digital stands for the integer part of calibration volume the short digit stands for the decimal part of calibration volume the u...

Page 8: ...VC tube inlet into the 4 Power adapter plugged into AC power fluid container while put the outlet into socket output terminal plugged into the fish tank head is around 2 meters DC IN socket of the dos...

Page 9: ...ng the setting amount the pump will stop Note After setting press Auto to run Parameters Delay From and To are 0 Parameter Run is not 0 Cycle quantitative add Set amount and time then the pump will ru...

Page 10: ...antitative add during a certain time Set amount and time then the pump will run cyclically during this time The pump will not work without the time you set Note Press auto to start and press auto agai...

Page 11: ...measure added volume during a certain time period 10ml measuring cylinder is delivered for free with the machine for more accurate flow rate a larger measuring cylinder can be used Pump is needed to b...

Page 12: ...o add nutrient solution Ca Mg KH etc Tank volume 360L Creature SPS 6 LPS 5 Fish 4 Other 8 Dosing solution Calcium Magnesium KH Dosing amount 20ml take Cal as an example Dosing times 4 times day How to...

Page 13: ...osing pump s actual status 9 Specifications Model F01A DC F01A STP Pump head KPP KAS Pump head life 1000 hours Motor life DC motor 800 hours Stepper motor 5000 hours Adapter Input AC 100 240V 50 60Hz...

Reviews: