Kamoer KH Carer Quick Start Manual Download Page 11

10 

Packing list 

No. 

Name 

Specification 

Unit 

Qty 

01 

Device 

KH Carer 

pcs 

02 

Power adapter body 

DC24V 1.9A 

pcs 

03 

Power adapter plug 

US/UK/EU/AU 

pcs 

04 

pH4 calibration solution 

25 ml 

pcs 

05  pH9. 18 calibration solution 

25 ml 

pcs 

06 

KH detection reagent 

20 ml 

pcs 

07 

Measuring cup 

100 ml 

pcs 

08 

Seawater sample tube 

Green 3 * 5mm; PVC 

meter 

09  KH detection reagent tube 

Yellow 3 * 5mm; PVC 

meter 

10 

KH Dosing tube 

Black 3 * 5mm; PVC 

meter 

11 

KH addition outlet tube 

Blue 3 * 5mm; PVC 

meter 

12  Waste liquid discharge tube 

Red 3 * 5mm; PVC 

meter 

13 

Ruhr joint 

1 / 8 butt joint B 

pcs 

14 

Filter head 

 

pcs 

15 

Magnetic stirrer 

10*20mm 

pcs 

16 

Electronic scale 

Measuring range 3kg 

pcs 

17 

Syringe 

10 ml 

pcs 

18 

Burette holder 

 

pcs 

19  Plastic graduated cylinder 

10mL 

pcs 

20 

Glass graduated cylinder 

5mL 

pcs 

21 

Quick start guide 

English 

pcs 

Summary of Contents for KH Carer

Page 1: ...KH Carer Quick Start Guide A0 2022 02 09 Kamoer Fluid Tech Shanghai Co Ltd www kamoer com...

Page 2: ...also automatically adjust KH value according to the test results 1 2 3 4 5 6 7 8 9 10 11 12 1 Seawater sampling interface connected to sea water tank 2 Add KH detection reagent interface and connect t...

Page 3: ...and the power down parameters are not lost Support IOS and Android remote Wi Fi control and local Bluetooth control Support the solution bottle capacity monitoring function and push the alarm when the...

Page 4: ...the KH detection reagent that can be used directly is purchased this step can be ignored The following describes the dilution method of KH detection reagent concentrate 1 The electronic scale measure...

Page 5: ...n download corresponding to the icon Note This App supports Apple devices with iOS9 1 and above and Android devices with Android4 4 and above Register account Open the App select the phone registratio...

Page 6: ...follows 1 Make sure that the wireless router is connected to the Internet the Bluetooth function of the mobile phone is turned on and connected to the 2 4G Wi Fi hotspot of the wireless router the dev...

Page 7: ...press the corresponding device icon on the device list page the Remove icon will pop up at the bottom click the Remove icon to unbind First use After the installation of KH Carer it is the first time...

Page 8: ...lashing you can reduce the intensity of magnetic stirring on the App 5 Waste liquid discharge pump Manually operate the waste liquid discharge pump until the liquid in the beaker is drained If the was...

Page 9: ...me the pH electrode should be stored with an electrode cap with protective solution 7 The pH electrode has a service life which varies according to the service environment Generally it is about one ye...

Page 10: ...t 2935g not including power adapter Power Adapter Input 100VAC 240VAC Output DC24V 1 9A Interface Wi Fi Bluetooth CAN Spare Working environment Temperature 0 70 Humidity 10 90 non condensing Storage e...

Page 11: ...Green 3 5mm PVC meter 2 09 KH detection reagent tube Yellow 3 5mm PVC meter 2 10 KH Dosing tube Black 3 5mm PVC meter 2 11 KH addition outlet tube Blue 3 5mm PVC meter 2 12 Waste liquid discharge tub...

Page 12: ...The free maintenance service provided during the warranty period includes free repair free provision and replacement of faulty parts and replacement of products that cannot be repaired with products o...