Kamoer AIP WIFI Quick Start Manual Download Page 5

About AIP WIFI 

AIP series peristaltic pump is using stepping motor control, commonly used in low traffic and 

high precision setting, configure the touch screen 480 x 272, powerful, easy to operate.

 

In addition to touch screen control, AIP WIFI also contains a variety of external control methods, 

including mobile phone App control via WIFI, analog control (0~5V, 4~20mA), RS485 control and 

CAN control.

 

1

2

3

4

5

6

 

Figure 1-1 Exterior look 

Definition of button: 

1. Clockwise rotation button:

 press the setting pump to rotate clockwise (to be used when 

the pump stops) 

2. Counterclockwise rotation:

 press the button to set the pump to rotate counterclockwise 

(to be used when the pump stops) 

3.  Quick  emptying  button:

  it  is  used  in  the  pump  line  calibration  interface.  After  pressing 

down, the pump runs quickly to empty, and then press down again to stop emptying 

4.  Acceleration  button:

  the  pump  speed  increases  after  pressing  down,  and  the  modified 

speed can be used continuously (in continuous mode). 

Summary of Contents for AIP WIFI

Page 1: ...AIP WIFI smart peristaltic pump Quick Start Guide A1 2022 03 15 Kamoer fluid tech Shanghai Co Ltd www kamoer com...

Page 2: ......

Page 3: ...which can be determined by turning the device off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna...

Page 4: ...ules to avoiddanger If you find any visible damage please do not switch on Be sure not to use in humid environment avoid damage by short circuit Temperature changes or mechanical wear may cause the in...

Page 5: ...ntrol 1 2 3 4 5 6 Figure 1 1 Exterior look Definition of button 1 Clockwise rotation button press the setting pump to rotate clockwise to be used when the pump stops 2 Counterclockwise rotation press...

Page 6: ...liquid level sensor expansion component so that the instrument has the function of liquid level detection 3 Temperature sensor interface used to plug the temperature sensor expansion component so tha...

Page 7: ...chine contains 0 5V analog control 4 20mA analog control Specific analog control pins are defined as follows Pin Connection name Parameters are defined 1 Analog quantity control direction DIR High lev...

Page 8: ...search for kamoer pumps find the app download of the corresponding icon Kamoer Pumps App supports Android 4 4 and above and supports iOS 9 1 and above View the tutorial Click the icon on the top left...

Page 9: ...d at a time Router mode STA Cannot see the dosing pump Wi Fi in the mobile Wi Fi list the user controls the dosing pump by connecting the wireless router After the configuration is successful multiple...

Page 10: ...ontrol function For the specific operation method please refer to the AIP CAN operation remote protocol Technical parameters Drive Stepper motor Power Input AC100 240V Output DC36V 4 3A Weight 7 6Kg I...

Page 11: ......

Page 12: ...n one year from the date of purchase The free repair service provided during the warranty period includes free repair free replacement and replacement of faulty spare parts and products that cannot be...