background image

Tapping capacity 35 K (10-45 °C)

DI0000040

40

35

30

25

20

15

10

5

0

18

2

4

6

8

10

12

14

16

20

22

24

A

B

50 °C

55 °C

60 °C
65 °C
70 °C

75 °C

80 °C

85 °C

Item

Description

A

Return temperature °C

B

Tapping capacity in litres/minute (l/min)

Cold water warming 40 K (10-50 °C)

DI0000041

1200

200

400

600

800

1000

0

2

4

6

8

10

12

14

16

18

20

22

24

1400

1600

A

C

B

D

70 °C

60 °C

55 °C

65 °C

75 °C
80 °C
85 °C

Item

Description

A

Primary heating demand in litres/hour (l/h)

B

Primary heating supply temperatures

C

Tapping capacity in litres/minute (l/min)

D

Max range

Tapping capacity 40 K (10-50 °C)

DI0000042

40

35

30

25

20

15

10

5

0

18

2

4

6

8

10

12

14

16

20

22

24

A

B

55 °C

60 °C

65 °C

70 °C
75 °C
80 °C
85 °C

Item

Description

A

Return temperature °C

B

Tapping capacity in litres/minute (l/min)

Cold water warming 45 K (10-55 °C)

DI0000043

1200

200

400

600

800

1000

0

2

4

6

8

10

12

14

16

18

20

22

24

1400

1600

A

C

B

D

75 °C

65 °C

60 °C

70 °C

80 °C
85 °C

Item

Description

A

Primary heating demand in litres/hour (l/h)

B

Primary heating supply temperatures

C

Tapping capacity in litres/minute (l/min)

D

Max range

32 

 |  

Combi Port E D

  |  

Installation and operation manual

Summary of Contents for uponor Combi Port E D

Page 1: ...Combi Port E D EN Installation and operation manual CD0000XXX CD0000390...

Page 2: ...ponents devices 14 5 5 Filling flushing and venting 14 6 Operation 15 6 1 Hydraulic balancing on the manifold 15 6 2 Constant pressure pump control 15 6 3 Combi Port E mobile application 16 6 4 Commis...

Page 3: ...products approved or specified by Uponor is not connected to or used with non Uponor products parts or components except for those approved or specified by Uponor and does not show evidence of tamperi...

Page 4: ...ble vapours or gases Uponor cannot accept any responsibility for damage or breakdown that can result from ignoring these instructions 2 2 Standards and regulations Note The installation must be carrie...

Page 5: ...for details of where and how they can take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This pr...

Page 6: ...nsists of many individual components which are described below The unit can also be equipped with accessories like heat meters and components from the Uponor room temperature control system both wired...

Page 7: ...e following accessories are optional Their use completes the product portfolio The application is described in more detail in the following chapters Port Base and pipe connection set CD0000367 Port Ba...

Page 8: ...m control functions This list shows available functions for the different systems Basic Functions Wave Pulse Base Pulse Base PRO Autobalancing Cooling function Modularity Installation and configuratio...

Page 9: ...port E D UFH unless nothing else is mentioned The insulation mounted in the unit is removed in the illustrations only to show all components and increase the understanding The installation of Combi Po...

Page 10: ...escription A Flat gasket 1 Place the flat seals on to the ball valves screw connection 2 Tighten the swivel nuts Connect the primary supply pipes Note Install the pipes in accordance with planning doc...

Page 11: ...emperature control Note Visit the Uponor download centre for more information regarding the installation and configuration of Uponor Smatrix and Uponor Base flexiboard 4 4 Heat interface unit with Por...

Page 12: ...sired fittings 2 Connect the underfloor heating pipes to the underfloor heating manifold by using desired fittings Connect the compression fittings SI0000324 1 2 1 Cut the pipe in required length 2 Co...

Page 13: ...re set pressure is defined based on the calculated static height from the expansion vessel to the highest point in the heating system DI0000023 The pressure in the vessel is pre set to1 0 bar which no...

Page 14: ...is installed The room temperature signal can also be activated via the individual room control Uponor Smatrix or Uponor Base flexiboard 5 5 Filling flushing and venting Note Switch off the pump befor...

Page 15: ...gulation valve according to the design calculation 5 Consider the planning documentation 6 2 Constant pressure pump control Note Please read the installation manual from the pump manufacturer CD000039...

Page 16: ...pp Likewise all settings for domestic water and heating are made via the app Combi Port E app PDF SI0000301 1 Download the Combi Port E app It is available both for iOS and Android mobile devices 2 Sc...

Page 17: ...ing mode Automatic reconnect Connect when the application returns to the foreground Polling interval Interval in seconds in which displayed values are updated Increase value to consume less battery ch...

Page 18: ...r OFF Room controller POSSIBLE SETTINGS Operating mode Control mode Time program Heating curve optional ECO mode heating DISPLAYED VALUES Supply secondary Return secondary Outdoor temperature optional...

Page 19: ...ovided via the central house connection and distribution line The heat interface unit is equipped with a central shut off ball valve for cold water F As an option there is a shut off ball valve for in...

Page 20: ...display Hotwater Check the controller setting Check setpoints via the App in the display Hot water Waiting time for hot water is too long Check the pump setting in the central heating system Pump set...

Page 21: ...al heating circuit pump not working Check that the central heating circuit pump is working and correctly set Central strainer is dirty Clean the central strainer Heating system is not working correctl...

Page 22: ...ure 10 bar Connection DN 15 G1 Power connection 230 V 50 60 Hz Electrical current max 0 44 A 9 2 Electrical connection controller Electrical net connection 230 V AC Contacts Description Marking L X1 P...

Page 23: ...RS485 interface 4 pin terminal X14 For terminal output or Modbus RTU communication Modbus RTU For data output and possibility to change setting values For communication a Modbus RTU master program dow...

Page 24: ...2 BN BU M 3 BN BU M 4 BN BU M 5 BN BU M 6 BN BU 12 L L PUMP L N BOILER 24 V L N Power GPI a b a b OK 2 1 T 165 T 163 T 169 T 168 OK T 166 T10 T10 D X7 X3 P J G E N M M G D H I B E N C M N A A M L D F...

Page 25: ...pply secondary X Heating return secondary Y Domestic hot water to apartment DHW Z Cold water from riser CW AA Circulation optional AB Uponor Smatrix Wave Pulse room controller AC Zone valve for limiti...

Page 26: ...single room thermostat V W X Y Z AA T10 T10 D X7 X3 P J G E N M M G D H I B E N C M N A A M L D F G T O R T3 X4 M T2 V2 T4 T8 X21 K B V1 Q M T8 X21 K T1 U S WD0000035 26 Combi Port E D Installation a...

Page 27: ...Contact Description Colour cable tie X21 Heating return primary Blue X22 Cold water from riser CW Green X25 optional X26 optional Temperature sensors Contact Description Colour cable tie T1 Domestic h...

Page 28: ...E D UFH Combi Port E D X 24 plates Pressure losses Heating side primary DI0000027 0 80 0 70 0 60 0 50 0 40 0 30 0 20 0 10 0 00 100 200 300 400 500 600 700 800 900 1000 1100 1200 A B C Item Description...

Page 29: ...C 85 C Item Description A Primary heating demand in litres hour l h B Primary heating supply temperatures C Tapping capacity in litres minute l min D Max range Tapping capacity 35 K 10 45 C DI0000030...

Page 30: ...ting supply temperatures C Tapping capacity in litres minute l min D Max range Tapping capacity 45 K 10 55 C DI0000034 40 35 30 25 20 15 10 5 0 2 4 6 8 10 12 14 16 18 20 22 60 C 65 C 70 C 75 C 80 C 85...

Page 31: ...nd other internal external fixtures must be included Domestic hot water side secondary DI0000038 1 00 0 40 0 50 0 60 0 70 0 80 0 90 0 30 0 20 0 10 0 00 2 0 4 0 6 0 8 0 10 0 A B 12 0 14 0 16 0 18 0 20...

Page 32: ...ting supply temperatures C Tapping capacity in litres minute l min D Max range Tapping capacity 40 K 10 50 C DI0000042 40 35 30 25 20 15 10 5 0 18 2 4 6 8 10 12 14 16 20 22 24 A B 55 C 60 C 65 C 70 C...

Page 33: ...70 C 65 C 75 C 85 C Item Description A Primary heating demand in litres hour l h B Primary heating supply temperatures C Tapping capacity in litres minute l min D Max range Tapping capacity 50 K 10 6...

Page 34: ...cribes the residual pressure Heating heat exchanger values Primary heating supply 70 C Primary KW Supply C Return C T l h 1 0 70 0 41 0 29 0 29 6 2 0 70 0 41 0 29 0 59 3 4 0 70 0 41 0 29 0 118 6 8 0 7...

Page 35: ...Combi Port E D Installation and operation manual 35...

Page 36: ...to make changes without prior notification to the specification of incorporated components in line with its policy of continuous improvement and development www uponor com 1105741 v1_03_2020 Producti...

Reviews: