background image

5

Both 

CombiMag

 three-port valves should be in the CIRCULATE position.

2

Select the required direction of flow and position the pump flow 
reverser lever in that direction.

1

Place the 

CombiMag

 power flushing filter adjacent to the power 

flushing pump on a suitable drip tray.

The power flushing pump can circulate the system water in either direction 
by operation of the flow reversing lever. However we suggest that the initial 
set-up is such that the 

CombiMag

 filter is installed before the boiler to offer 

the boiler a higher level of protection in the early stages of the power flush.

4

Using the power flushing pump standard flow and return hoses connect 
both the pump and the top connection on the 

CombiMag

 to the heating 

system.

3

Install the filter on the flow from the flushing pump using the short 
(1 ½ metre) hose supplied. Connect the flow to the lower connection on 
the filter.

5

Grip the cylinder lid and handle with one hand. Whilst wearing 
disposable gloves, grip and slide the magnetite sludge down and off 
the magnet (see pictures below).

3

Remove the securing ring from the top of the cylinder and, gripping the 
handle firmly, carefully lift out the magnet.

Note: It is advisable to only remove a proportion of the deposits with each 
stroke, starting at the lower end of the magnet, rather than all at the same 
time. Clean the end of the magnet.

Note: the magnet is very powerful and is strongly attracted to steel surfaces. 
Take care not to trap fingers and avoid contact with sensitive equipment

.

1

Turn on the power flushing pump and immediately check all 
connections, and the top of the 

CombiMag

 cylinder for leaks.

It is not necessary to remove all deposits during the intermediate cleans 
whilst power flushing. However, to ensure a long life the magnet should be 
thoroughly cleaned and dried at the end of each job.

4

Inspect the magnet for collected deposits and, if necessary, clean as 
follows:

6

Collect the sludge in a suitable container for later disposal.

7

Re-assemble the CombiMag ensuring that the magnet locates within 
the circular recess at the base of the cylinder, and turn both three-port 
valves back into the CIRCULATE position.

OPERATION DURING POWER FLUSH

8

Repeat the inspection and cleaning procedure as required during the 
flushing process.

CLEANING THE MAGNET

2

After initial circulation for approximately ten minutes, turn both three-
port valves 180° into the BYPASS position.

CAUTION - The CombiMag contains a strong magnet and generates a very 
powerful magnetic field. When removed from the cylinder, keep away from 
electronic equipment, watches, mobile phones, credit cards etc.

BUILDING PUMPS

SINCE 1992

Kamco

CombiMag

Clearflow Pump

FLOW

RETURN

boiler

Extra hose supplied
with CombiMag

*Flow and return may be connected at circulator pump connectors or using the 

Kamco CP2 Pump Head Adapter

, or at many alternative points in the system.

Kamco

CombiMag 

 |  Operating Instructions

CombiMag SOLO TECHNICAL DATA

Strength of magnet:  

11,000 gauss

Length of magnet:  

400mm

Magnet surface area:  

201 sq cm

Weight of unit:     

4.95 kg

Overall height:  

475mm

Overall width:  

215mm

Overall depth:  

245mm

MAGNET
BEFORE &
AFTER USE

Kamco

TEL: 01727 875020  |  WWW.KAMCO.CO.UK  |  [email protected]

Kamco, Unit 9, Curo Park, Frogmore, St Albans. Herts, AL2 2DD, UK  © KAMCO Ltd.

KAMCO and CLEARFLOW are registered trademarks of Kamco Limited UK.

Example connections

at Circulator Pump*