background image

cleanIng and replacIng 

fIlTerS

Filters must be cleaned from time to time 
to remove the fine dust particles that have 
been collected. 

1. Remove the dust container from the 
  unit by pressing down on the “Press and 
  Lift” button 

on/off

cord

press

& lift

up

down

2. Then press the “Push to Empty” button.  
  The bottom of the container will  
  release. Take off the filter bracket by 
  holding onto the shaft and turning the 
  filter in an anti-clockwise direction and 
  the filter and its bracket will be released. 

3. To remove the metal filter bracket,  
  simply lift it vertically. The filter bracket  
  can be rinsed in luke warm water.  
  Ensure you let the filter bracket   
  completely dry naturally before next use.

4. Shake and tap the HEPA filter until  
  all the fine dust particles are removed.  
  However, after approximately 6 months  
  the HEPA filter should be replaced.

5. To place the filter back in the dust  
  container simply place the metal filter 
  bracket directly over the HEPA filter, 
  ensure that the metal filter holder is  
  completely dry before use. Ensure that  
  the grooves on the HEPA filter holder  
  and metal filter bracket fit into place. 

6. Simply place the filter unit in the dust  
  container lid and turn the filter unit in  
  a clockwise direction until it is clicked in 
  place. Close the bottom of the container.

7. Place the dust container back in the  
  vacuum cleaner for next use.

moTor proTecTIon fIlTer

The motor protection filter must always 
be in place when operating the vacuum 
otherwise damage to the motor may 
occur.

To replace the motor protection filter 
- remove the dust container. The motor 
protection filter is located at the bottom 
of the inner chamber. Pull the filter 
upward to remove then simply replace the 
new filter.

exHauST fIlTer

The exhaust filter should be cleaned every 
six months. Simply unclip the grill at the 
back of the vacuum cleaner and shake 
and tap the filter to remove any dust 
accumulated. Then relocate the filter and 
reattach the grill.

care and maInTenance

Always switch appliance off, then switch 
off at the power outlet and unplug the 
appliance prior to cleaning or replacing 
either filter.

To clean the outside of the unit, wipe the 
exterior with a soft, damp cloth. Never 
use an abrasive cleaner. 

cHecK and replace BoTH 

THe moTor proTecTIon 

and Hepa fIlTerS 

approxImaTely TwIce 

a year or wHen VISIBly 

clogged.

 

notes