OWDMANUAL 1114
KAM CONTROLS, INC.
4
S P E C I F I C AT I O N S
Media:
Crude oil, refined products and chemicals
Material:
Wetted parts - 316 stainless steel / titanium (Other materials available)
Fluid temp:
T
o 300ºF (149ºC) High temp model available to 600ºF (315ºC)
Electronics temp:
-40
º
F to 158
º
F (-40
º
c to +70
º
C) Temps below 0
º require heat tracing
Power requirements:
24 VDC/1 amp at 24 watts
Accuracy:
1% of full range**
Repeatability:
+/- 0.01%
Resolution:
+/- 0.01%
Minimum water detection:
100 PPM
Outputs:
4–20 mA
4-20 mA or 0–5 VDC
Alarm
relay
RS232/RS485
HART
Mounting:
½", ¾", 1" or 2" FNPT flow through
(Other sizes, including metric, are available)
2" MNPT seal housing
2", 3", or 4" flanged seal housing
Pressure ratings:
ANSI 150, 300, 600, 900, 1500
Flow conditions:
Well mixed in accordance with API MPMS Chapter 8, Section 2, Table 1
Sensor dimensions:
Ø1.5" x 4.5" to 14.5" (38mmh x 114mm to 368mm) depending on range
EX enclosures:
Sensor electronics - 3" x 6" x 3"
(76mm x 152mm x 76mm)
Shaft length:
12" to 36"
(305mm to 914.4mm)
Off-the-shelf lengths are 12", 24", and 36"
(609.6mm, 762mm, 914.4mm,)
Pipe Size:
½" to 48" (15mm to 1200mm)
Weight:
from 20 lbs. (9kg)
* The KAM
®
OWD
®
must be installed in accordance with API MPMS Chapter 8, Section 2, Table 1.
**If entrained gas is constant, its effect is factored out. If entrained gas is introduced or removed after OWD
®
calibration it will shift water cut measurement by approximately 1-2% for every 1% change in gas levels.