KAM KMH SERIES Instruction Manual Download Page 3

DMX-512 connection 

If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the first 
unit in a DMX chain. If you wish to connect a DMX controller with other XLR outputs you will need to use adapter cables. 
 

       

1 = ground      2 = minus signal (-)     3 = plus signal (+) 

 
Connect the DMX output of the first unit in a DMX chain with the DMX input of the next unit in the chain. Always connect the the 
output of one unit with the input of the next unit until all units are connected. If you use a controller with 5 pin DMX connection you 
will need to use a 5 pin to 3 pin adapter.

 

 
Overhead rigging 
Important

 - the installation must be carried out by qualified service personal only. Improper installation can result in serious 

injuries and /or damage to property. Overhead rigging required extensive experience. Working load limits should be respected, 
certified installation materials should be used, the installed unit should be inspected regularly for safety. 

l

 

Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging and servicing. 

l

 

Locate the unit in a well ventilated spot, far away from any flammable materials and/or liquids. The fixture must be fixed

 at 

least 50cm

 from surrounding walls 

l

 

The device should be installed out of reach of people and outside of areas where persons may walk by or be seated. 

l

 

Before rigging make sure that the installation area can hold minimum point load of 10 times the device’s weight. 

l

 

The device should be well fixed; a free swinging mounting is dangerous. 

l

 

Do not cover any ventilation opening as this may result in overheating 

Before first time use, the unit should be inspected for safety. Inspection the unit regularly every year. 
 
 

Overview 

There are currently three different units in the Kam KMH series. These are the quad moving head KMH4, the dual head KMH2 
and the single head KMH1. 
 

  

 

The KMH series have been designed to link together in Master/Slave mode. Whether you have a four head, a two head or a 
single head unit, each of the individual moving heads can be accessed and operated as a single unit using the built-in settings, or 
via a DMX controller or DMX software. You will notice that each moving head has its own blue LED display and set of function 
buttons. Operation and selection of the correct mode for each head is very important to get the units to run in the way that you 
want them to perform. 

 
In simple terms, the individual heads can be operated in either Master/Slave mode (where all heads perform in exactly the same 
way) or in individual DMX mode (where each moving head is controlled separately). 
 
After connecting your Kam Moving Head unit to the mains, use the Function Setting menu on the unit to set the operating mode. 
 

 
 
 
 
 

 
 
 
 

Summary of Contents for KMH SERIES

Page 1: ...Dunstable Bedfordshire United Kingdom LU6 3EJ Telephone 44 0 1582 690600 Fax 44 0 1582 690400 Email mail lambaplc com Web www lambaplc com If this product is ever no longer functional please take it...

Page 2: ...ufficient power to constitute a risk of electrical shock to persons Caution to prevent the risk of electric shock do not attempt to open the unit No user serviceable parts inside Refer all servicing t...

Page 3: ...device should be installed out of reach of people and outside of areas where persons may walk by or be seated l Before rigging make sure that the installation area can hold minimum point load of 10 ti...

Page 4: ...nnect a DMX cable from the DMX Output of the Master unit to the DMX Input of the next unit then another DMX cable from the second unit s DMX Output to the DMX input of the next unit and so on for all...

Page 5: ...0 255 Tilt Channel Function Value Function 1 Dimmer 0 255 From dark to bright 2 Strobe 0 255 From slow to fast 3 Red 0 255 Red from dark to bright 4 Green 0 255 Green from dark to bright 5 Blue 0 255...

Page 6: ...e second head s DMX address and then another 9 digit difference between the second head and the third head This changes to a 13 digit gap needed when operating in 13 channel DMX mode The tables below...

Page 7: ...Light source 2 x 10w CREE 4 in 1 LED Colours Red green blue and white Control setting 4 buttons plus function setting LED display x 2 Finish Powder black metal housing Operating temperature 10 40 DMX...