INSTALLATION CHECKLIST

The Installation technician must check the following items before leaving the 

premises.

Ensure the physical installation is complete including:

 

Flue installation

 

Media Installation

 

Gas type conversion (If required)

Ensure gas inlet and outlet pressure values are set according to the compliance plate
Please contact the relevant authority if gas inlet pressure is insu

ffi

cient

Ensure that a gas leakage (pressure) test is carried out before commissioning the heater

Any other test required by relevant authorities are carried out
Ensure that remote control is paired with the heater  

(Please refer to remote control instructions, page 20)

Commission the heater and ensure the operation is satisfactory

If you have any problems carrying out any of the tasks above or if the heater operation is not satisfactory, please contact Kalora.

Kalora Pty Ltd.

Head O

ffi

ce

58-60 Access Way,

Carrum Downs VIC 3201

Australia

(03) 8579 5900

www.kalora.com.au

Model Name 

SORRENTO

Model Number 

KAGAS10

Ka.Sor Version: 

1.6 

8/4/19

The copy of the manual provided with your Kalora appliance was current 

at the time of manufacture, on occasion there is need for revision 

therefore we recommend checking our website to ensure the version 

supplied is the most current

Summary of Contents for KAGAS10

Page 1: ...vant authorities are carried out Ensure that remote control is paired with the heater Please refer to remote control instructions page 20 Commission the heater and ensure the operation is satisfactory...

Page 2: ......

Page 3: ...uality finely crafted gas space heaters will offer many years of reliable performance This instruction manual has been developed to ensure optimum performance from your Kalora gas space heater It s ve...

Page 4: ...EL SURFACE E G SOLID FLAT FLOOR OR SUPPORTING BOARD THAT SUPPORTS THE WHOLE BASE OF THE UNIT WARNING 1 THE KALORA SORRENTO HAS A PRIMARY SAFETY GUARD FITTED IN FRONT OF THE GLASS DOOR THIS SAFETY GUAR...

Page 5: ...s pressure 0 95 kPa 2 41 kPa Nominal maximum gas consumption 25 5 MJ h 23 0 MJ h Turn down gas pressure 0 40 kPa 0 68 kPa Turn down gas consumption 17 0 MJ h 12 7 MJ h Main burner injector 2 3mm 1 4mm...

Page 6: ...eating Aust Pty Ltd Head Office 58 Access Way Carrum Downs 3201 Australia Warehouse Lot 1 Melbourne Cresent Seymore VIC 3660 Australia 61 3 5792 2388 www kalora com au Model Name Sorrento Model Number...

Page 7: ...DIMENSIONS mm 484 472 283 842 790 32 48 620 1245 1035 1294 TRUE R30 TRUE R25 297 80 10 100 175 955 1234 410 484 472 283 842 790 32 48 620 1245 1035 1294 TRUE R30 TRUE R25 297 80 10 100 175 955 1234 41...

Page 8: ...e and also include materials that are behind non combustible materials If you are not sure of the combustible nature of a material consult your local fire officials Minimum clearance for a combustible...

Page 9: ...r a combustible surface FLOOR MOUNT INSTALLATION MID MOUNT INSTALLATION A Mantel height from top of the fireplace opening mm 360mm B Side Wall 80mm C Ceiling 1000mm D Mantel Depth max 330mm E Front fl...

Page 10: ...l V A 1 x 90 Elbow 1 x 900mm flue pipe B 1 x 90 Elbow 1 x 900m flue pipe 1 x 900mm flue pipe C 1 x 90 Elbow 3 x 900m flue pipe 2 x 900mm flue pipe D 1 x 90 Elbow 4 x 900m flue pipe 2 x 900mm flue pipe...

Page 11: ...nal I Mechanical Air Inlet M Gas Meter P Electricity meter or fuse box Z Fan assisted appliance only ORANGE SHADING INDICATES PROHIBITED AREA FOR FLUE TERMINALS PROHIBITED AREA FOR FLUE TERMINALS INST...

Page 12: ...ces over 200 MJ h input up to 250 MJ h input 1500mm Appliances over 250 MJ h input 1500mm K From a mechanical air inlet including a spa blower 1500mm N Vertically below an openable window non mechanic...

Page 13: ...Glass Burner Default 105mm 265mm 120mm Using the glass provided fill the burner up to 10 15mm deep evenly spread across the tray Use 3 Lava rocks provided and place them according to the distances bel...

Page 14: ...ion as depicted in the image below Vermiculite Burner with Driftwood Vermiculite Burner with Pebbles Place the logs and pebbles provided in their designated location Apart from the burner media no oth...

Page 15: ...ircled Dimensions On Drawing MUST BE INSPECTED Dimensional Tolerances Unless Otherwise Stated Are KGSH Sorrento_Manual Two Decimal Places 0 05 One Decimal Place 0 1 Zero Decimal Places 0 5 Plaster Bra...

Page 16: ...imal Places 0 5 Stan Off SCALE 1 10 A3 Dimensions in Millimeters Title COPYRIGHT and CONFIDENTIAL Material Grade Treatment Gauge Material Type Colour Weight g Finish Auth e Change Detail J Young 2 18...

Page 17: ...g Finish Auth Date Issue Change Detail J Young 1 0 20 02 18 Drw D Wickramarathna For Complete Dimensions Refer to CAD File PART Circled Dimensions On Drawing MUST BE INSPECTE KGS Pla SCALE 1 10 A3 Tit...

Page 18: ...replace the pilot injector using the injector provided in the conversion kit STEP 2 Please refer to the compliance plate product specification table to ensure the correct injector size STEP 8 Please...

Page 19: ...propane gas type Inlet and outlet test points may be used to check the pressure while doing the adjustments STEP 13 A SIT pressure adjustment tool may be used to adjust the pressure Alternatively a ph...

Page 20: ...er with the locating lugs in the body of the heater insert slowly until the rear of the fascia is in the preferred position Lower the outer fascia and the mounting mechanism will self locate onto lugs...

Page 21: ...or set indicator When the remote is ON the programmed set temperature will be displayed on the centre digits When the remote is off only the room temperature top digits will be displayed Transmit indi...

Page 22: ...s not require that the time and day of the week are set Flame height and fan speed The flame height and fan speed are not manually adjustable The flame height and fan speed are set by the remote accor...

Page 23: ...te programming The LCD will display PROG Pd and the time at which the remote is currently set MO will flash Period 1 can now be set Setting The Day Of The Week 2 First you must choose which day of the...

Page 24: ...m 4 is set press OK and the program for the selected day s will be set The remote will now automatically turn off Repeat the programming process for any other periods days that are required Settings C...

Page 25: ...Component compartment Vacuum and wipe out dust cobwebs debris or pet hair Use caution when cleaning these areas Screw tips that have penetrated the sheet metal are sharp and should be avoided Remove a...

Page 26: ...l STEP 1 Remove the fascia See instructions on page 15 of this manual STEP 3 Some adjustments alterations can be done via the front panel opening To access the components this way remove the screws an...

Page 27: ...ilot assembly from the firebox STEP 5 Ensure that any media has been removed from the burner To remove the burner from the firebox remove 6 screws as shown in the image below STEP 6 Remove two screws...

Page 28: ...t the heater If the fire fails to reignite contact Kalora Outdoor heavy wind conditions The heater is designed to safely shutdown during heavy wind conditions If this occurs please wait until conditio...

Page 29: ...27 WIRING DIAGRAM...

Page 30: ...030700007 9 Non combustable board top 1 SG030700008 10 Power cable gromet 1 SG030700009 11 Case no parts avaliable 1 SG030700010 1 3 4 6 7 11 9 8 2 5 10 ITEM NO Part No Part Name QTY 1 Primary guard 1...

Page 31: ...flextive panel left 1 SG030700023 14 Reflextive panel back 3 SG030700024 15 Reflective panel right 1 SG030700025 16 Firebox casing No Parts Avaliable 1 SG030700026 SORRENTO EXPLODED DIAGRAM GAS SPACE...

Page 32: ...1 1 SG030800014 15 Loom over temperature switch 2 1 SG030800015 16 Loom room fan 1 SG030800016 17 Pilot burner ground wire 1 SG030800017 18 Gas valve modulating wire 1 SG030800018 19 See internal gas...

Page 33: ...10 11 Pilot burner 1 SG030900011 12 Pilot burner gasket 1 SG030900012 13 Pilot burner injector natural gas 1 SG030900013 14 Pilot burner injector LPG 1 SG030900014 15 Pilot burner gas line 1 SG0309000...

Page 34: ...2 SG031000004 E Grey Pebble 3 SG031000005 F Black Pebble 1 SG031000006 G Lava Rock SG031000007 H Sand Pebble SG031000008 I Log 1 SG031000009 J Log 2 SG031000010 K Log 3 SG031000011 L Log 4 SG031000012...

Page 35: ...h as to make the gas log fire unfit for normal home use and you comply with the requirements below regarding making a claim then subject to the exclusions below we will or will arrange to replace or r...

Page 36: ...clude the model number of the gas log fire the place price and date of purchase and reasonable details of the defect including both indoor and outdoor images of the installation if the gas log fire ha...

Reviews: