HOMEOWNERS GUIDE
Bath with Airjets
1096755-5-
D
12 of 16
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.
Symptoms
Probable Causes
Recommended Action
7. Blower motor runs but no air
bubbles are formed.
A. Blower motor inlet is blocked.
A. Clean blower motor inlet.
B. Air jets are clogged.
B. Use a small between-the-teeth
dental brush and white vinegar.
Dip the brush in the vinegar,
brush the hole, rinse the brush
in clean water, and then use the
wet rinsed brush to rinse the
hole.
C. Check valve does not work.
C. Replace the check valve. Refer
to your installer or wholesale
dealer.
D. Blower motor does not work.
D. Replace the blower motor. Refer
to your installer or wholesale
dealer.
E. Control does not work.
E. Replace the control. Refer
to your installer or wholesale
dealer.
8. Blower motor operates, air
bubbles are formed, zone
controls work, but variable
speed feature does not work.
A. Blower motor inlet is blocked.
A. Clean blower motor inlet.
B. Loose, disconnected, or
damaged wiring harness.
B. Check wiring for proper
connections. Replace the wiring
harness if necessary. Refer
to your installer or wholesale
dealer.
C. User keypad does not work.
C. Replace the user keypad. Refer
to your installer or wholesale
dealer.
D. Blower motor does not work.
D. Replace the blower motor. Refer
to your installer or wholesale
dealer.
E. Control does not work.
E. Replace the control. Refer
to your installer or wholesale
dealer.