9. Test Run the Whirlpool
Check all electrical connections.
Make sure all union connections to the pumps and heater are securely hand tightened.
Verify that the pump banding straps have been cut, and that the pump controls are resting directly
on the subfloor. Ensure that the rubber isolation feet are in place.
Turn electrical power to the whirlpool on.
Fill the whirlpool to a level at least 2
″
(5 cm) above the top of the highest jet.
Operate the whirlpool for 5 minutes (refer to the
″
Operating Sequence
″
section) and check all
whirlpool piping connections, on the back side, for leaks.
Turn on each of the whirlpool features and verify proper function. Check for any water leakage on
the whirlpool’s back side.
For additional information on whirlpool operation, see
″
Confirm Proper Operation
″
section.