1080602-2-A
Page 3 of 6
1. REMOVE PIPE PLUG
2. INSTALL SPOUT
Rough
Deck
Tile
1-1/4” (3.2 cm)
Remove the plaster guard from the spout supply tube.
Cut off the spout supply tube 1-1/4” above the rim, finished
deck, or tile.
Remove all burrs from the spout supply tube to prevent
damage to the O-ring seal on the spout sleeve assembly.
WARNING: Risk of personal injury.
Lines will be
pressurized. Do not lean over pipe plug when turning or
removing the plug.
Ensure that the valves are closed (cold - fully
counterclockwise, hot - fully clockwise).
Turn off the main water supply.
Wrap a towel around the pipe plug to prevent water spray.
Important!
Water will purge from the supply tube when you
remove the plug.
Carefully remove the pipe plug.
CLOSE
COLD
CLOSE
HOT
3/8” Pipe Plug
P24403, P24404,
P24405
Deck Mount Bath Set
Questions? Problems? For additional assistance, please contact Kallista's Customer
Service Department at 1-888-4KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.
INSTALLATION
INSTRUCTIONS