INSTALLATION INSTRUCTIONS
One™ Deck-mount
Bridge Kitchen Faucet
1102265_2_A
4 of 4
Questions? Problems? For additional assistance, please contact Kallista’s Customer
Service Department at 1-888-4KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.
INSTALL The SUPPLIeS
Hot
Cold
3" (7.6 cm)
or Larger
Optional Sidespray
Supply Outlet
CAUTION: Risk of restricted water flow and product damage.
Use extreme care to avoid kinking and
twisting the supply hoses. The supply hoses must not be taut after installation.
NOTe:
If the sink installation requires that you coil the supply hoses to obtain a good connection, maintain an
inside coil diameter of at least 3″ (7.6 cm).
NOTe:
DO NOT remove the plug from the optional sidespray supply outlet unless you are installing the optional
sidespray.
Carefully position the hot and cold water supplies so they will not interfere with other hoses or items below
the mounting surface.
Connect and tighten the supply hoses to the supply stops. Left is hot, right is cold.
INSTALLATION CheCkOUT
Aerator
AeratorTool
Verify that all connections are tight and the handles are in the OFF position.
Turn on the main water supply.
Check all connections for leaks. Repair as needed.
Turn both handles to the ON position and allow the water to run through the spout to remove any debris.
Turn both handles to the OFF position.
NOTe: If water flow is restricted: Using the aerator tool (provided), turn the aerator clockwise to remove it from
the spout, remove the debris, then reinstall the aerator. Retain the aerator tool for future use.