background image

15

KD-070/50 SERIES

KD-070/50 SERIES

KALE ELECTRONIC GLASS DOOR LOCK

KALE ELECTRONIC GLASS DOOR LOCK

Changing the door on the left or right side.
1. Open the battery cover.
2. Insert the screwdriver into the hole.
3. Remove the screws of the installed one.
4. Pull out the front body to remove.
5. Turn it 180 ° and install back with screw.

1. Passcode button
2. Start / End button
3. Card reading section
4. Reset button
5. 9V emergency power terminal

9V emergency power terminal: 

In case of battery depletion, you can open the door using a 9V battery.

Reset function: 

The temporary program error can be resolved by pushing the reset button with a 

pointed object through the hole. (Pin code is not changed by this process)

Card reading section: 

Touch your card to the device to open the door.

On / Off button: 

 Single button is used to open or close the door.

Manual operating device: 

 Used to open the door manually (for fire or other emergencies)

Fire detection sensor: 

The fire detection sensor exists to open the door automatically in case of 

fire. (60C±5C)

Lock latch (lock latch counterpart): 

Internal connection member of the door lock

Automatic lock internal sensor: 

When the automatic lock is set, a magnetic sensor is placed that 

locks the door automatically.

Enter button: 

Used for passcode entry, registering and card cancellation.

• Registering: 

 Press the Enter button once and then press any button on the 

remote control. The information about the success of the registry is given with the 
"Ding dong dang" sound (registering in 8 seconds)

• Delete: 

Press the Enter button once and then the "5" button twice. Finally, to 

complete, press the "*" button. 
* Remote controls can be registered up to 15.

• On / Off

The door opens or closes within 2 ~ 3 seconds after the button is pressed.
*Frequency: FM447.275Mhz * Battery: AAA Size X 2EA (CR2032 1EA)

* Keep the door open when checking and registering the normally registered 
passcode.
1. Open the battery cover in the internal body and press the button once. (A 
"Beep" sound is heard.)
2. Enter the new passcode. (3 to 19 digits can be registered.)
3. To complete the registration, press the "*" button.
(If the entry is successful, the "ding-dong-dang" sound is heard.)
• Perform before the light goes off to move onto the next stage (Within 15 seconds).

* Register the passcode with the same procedure as stated above.
* When the new passcode is saved, the current password will be automatically 
deleted.
• When the door is open, never fail to register or change the passcode.
• The passcode is set as "1234" at the factory. - After installation, change the 
passcode prior to using.

1. Open the battery cover in the internal body and press the button once. (A 
"Beep" sound is heard.)
2. Touch each card to be registered to the card reading part on the outer body. Up 
to 50 cards can be registered.
3. To complete the registration, press the "*" button. If successful, the 
"ding-dong-dang" sound is heard. (A "beep" sound on failure.)

• Setup (Glass door lock without the fixing plate)

Installation Tips!

1. Sprinkling a little water on the glass door allows you to make easier installation.
2. Depending on the status of the door, the existence of silicone coating on the door lock may help 
prevent slippage.

1. Battery cover
2. Enter button
3. Manual Operation Button
4. On / Off switch
5. Lock Latch
6. Automatic lock internal sensor

Outer Body

Inner Body

14

(Only the applied model)

• Only record the card issued by the manufacturer.
•Registering and using a transportation card or a credit card can lead to security problems, 
in this case in the event of any damage, you can not get A/S or receive compensation.

Açma/
Kapama 
Butonu

3- PART NAMES

5 - PASSCODE REGISTRATION

6 - PASSCODE CHANGE

7 - CARD REGISTRATION

4- REMOTE CONTROL USE

Summary of Contents for KD-070/50-100

Page 1: ...KALE ELEKTRON K CAM KAPI K L D KILAVUZU KALE K L T VE KALIP SANAY A KALE ELECTRONIC GLASS DOOR LOCK MANUAL KD 070 50 100 101 102 103...

Page 2: ...lama Fonksiyonu 08 Pil De i tirme Y ntemi 08 Yedek Piller ile Kap y A ma 08 Kanunun 11 Maddesinde T keticiye Sa lanan Se imlik Haklara li kin Bilgi 09 Servis Hizmetleri 09 KALE ELEKTRON K CAM KAPI K...

Page 3: ...alinde m rleri garanti edilemez ve r n normal al mayabilir r n rastgele s kmeyin Ar zaya neden olabilir Kendi kendinize makineyi s kt n zde do ru al mayabilir Gerekli ise m teri hizmetlerine ba vurun...

Page 4: ...Kap d meye bas ld ktan sonra 2 3 saniye i inde a l r veya kapan r Frekans FM447 275Mhz Pil AAA Size X 2EA CR2032 1EA Normal olarak kaydedilmi ifreyi kaydederken ve kontrol ederken kap y a k tutun 1 g...

Page 5: ...girer ve d ar dan giri yap lmaya al ld konusunda sizi uyar r ifreyi girin veya RF kart tak n ve alarm susturulacakt r Giri d mesine bas n 1 ve 3 d meleri d mesi 1 d mesi al ak ses i in birka defa ve 3...

Page 6: ...p oran nda bedelden indirim haklar ndan birini kullanabilir Orant s zl n tayininde mal n ay ps z de eri ay b n nemi ve di er se imlik haklara ba vurman n t ketici a s ndan sorun te kil edip etmeyece i...

Page 7: ...trol Function 17 Fire Detection Function 18 Battery Replacement Method 18 Opening the Door with Spare Batteries 18 Information about the Right of Choice Provided to Consumers as per 11th Article of th...

Page 8: ...emble the product It may cause a malfunction The machine may not work correctly if you disassemble it yourself If necessary contact the customer service Use the product in a place where there is no wa...

Page 9: ...utton is pressed Frequency FM447 275Mhz Battery AAA Size X 2EA CR2032 1EA Keep the door open when checking and registering the normally registered passcode 1 Open the battery cover in the internal bod...

Page 10: ...about a forced entry attempt from outside Enter the passcode or insert the RF card and the alarm will be silenced Press the Enter button 1 and 3 buttons button 1 button a few times for low level or 3...

Page 11: ...on the cost in the ratio of the fault all or the discounted amount of the paid amount will be immediately refunded back to the consumer All the costs incurred due to the use of the right of choice are...

Page 12: ...IN nvan Adresi Telefon Faks We hereby confirm that product is under the guarantee of KALE with this certificate for 2 two years The expected life of this product is 2 years The guarantee conditions co...

Reviews: