4)
Attach the coaxial cable from the VIDEO
OUT connector of the camera to the video in connector of the monitor.
NOTE: Ensure that the monitor is terminated in 75 ohm.
5)
With a screwdriver, loosen the positive (
+
) and negative (
-
)
terminal connectors on the terminal
block.
6)
Connect one lead of your power source to the positive terminal connector and the other to the
negative terminal connector.
NOTE: The terminal block is reverse polarity protected; therefore, for the camera to work, the power leads must
be connected to the correct terminals.
7)
Retighten the terminal connector screws until snug, ensuring that the power leads are secure.
8)
Turn the power source on.
NOTE: Power is now being supplied to the camera, and the PWR LED should be illuminated. If the PWR LED is
not illuminated, check the terminal block connections and power source.
S
ETUP
Figure 4 shows the parts of the camera.
A
B
D
LENS
VIDEO DC
AI EE
VIDEO
LEVEL
A-IRIS
OFF
ON
DC 12V
+ –
G
BLC
H
J
F
C
E
G
I
Top View
Rear View
Figure 4. Parts of the KTC-105
1 +8.5 VDC
2 No connection
3 Video signal
4 Ground
Figure 2. Connections for auto iris lens with built-in
EE amp.
1 Control (-) 2 Control (+)
3 Drive (+) 4 Ground
Figure 3. Connections for auto iris lens without
EE amp.