background image

 

2

 

1036024A / May 2001 

For Technical Support and Sales call 800-469-1676

 

 

KTC-105 B/W

 Camera

 

4) 

Attach the coaxial cable from the VIDEO 
OUT connector of the camera to the video in connector of the monitor. 

NOTE: Ensure that the monitor is terminated in 75 ohm. 

5) 

With a screwdriver, loosen the positive (

+

) and negative (

-

)

 

terminal connectors on the terminal 

block. 

6) 

Connect one lead of your power source to the positive terminal connector and the other to the 
negative terminal connector. 

 

NOTE: The terminal block is reverse polarity protected; therefore, for the camera to work, the power leads must 
be connected to the correct terminals.  

7) 

Retighten the terminal connector screws until snug, ensuring that the power leads are secure. 

8) 

Turn the power source on. 

NOTE: Power is now being supplied to the camera, and the PWR LED should be illuminated. If the PWR LED is 
not illuminated, check the terminal block connections and power source. 

S

ETUP

 

Figure 4 shows the parts of the camera. 

LENS 

VIDEO DC 

AI EE 

VIDEO 

LEVEL 

A-IRIS 

OFF 

ON 

DC 12V 

+   –  

 G 

BLC 

Top View 

Rear View 

Figure 4. Parts of the KTC-105 

1 +8.5 VDC 

2 No connection 

3 Video signal 

4 Ground 

Figure 2. Connections for auto iris lens with built-in 

EE amp. 

1 Control (-)  2 Control (+) 

         3 Drive (+) 4 Ground 

Figure 3. Connections for auto iris lens without 

EE amp.  