kaivac
cleaning
systems
TM
P a g e ǀ
2 3
www.kaivac.com
©2020 Kaivac, Inc. All Rights Reserved
4.1 t
RoUbLeshooting
4.0 Troubleshooting and Upkeep
CAUTION
:
Always unplug machine before lifting electric cover assembly.
Electrical
No Power to pump or
vac motor
Battery dead
Charge battery
Switch not “on”
Check switches for “on”
Switch breakers thrown
Press the breaker reset buttons
Building circuit overloaded
Check and reset circuit
Switch wires loose
Disconnect power and check for
loose wire
Connections loose
Disconnect power and check for
loose wire under panel
Electrical burning smell
Vac motor brushes worn
Remove vac motor and repair
Vac motor hung up
Release pressure on hose and jog
vac switch, or replace
Pump motor hung up
Release pressure on hose and jog
pump switch, or replace
Vacuum System
No/Weak vacuum
Vac tank full
Empty vac tank
Squeegee blades or wheels
worn
Replace wheels or blades and
check periodically
Float shutoff screen dirty
Spray off float screen to clean
Float ball stuck
Tap float and release/clean
Damaged hose
Cut and repair/replace
Dump hose plug missing
Contact dealer and replace
Access lid not right
Tighten lid hand tight
Vacuum hose plugged
Flush hose to remove debris
Too much liquid in vac hose Allow air in when vacuuming
Vac hose still wrapped
Unwrap vac hose fully
Exhaust plugged
Remove HEPA filter and clean
Leak in vac tank
If repairable, clean and dry affected
area and seal with silicone
HEPA filter clogged
Remove HEPA filter and clean
Moisture from exhaust
Vac tank full
Dump vac tank
Float shutoff missing
Replace
Excessive foam in vac tank
Use defoamer
AREA
PROBLEM
POSSIBLE CAUSE