Controller
Electrical Control System
165
Name and function of LCD on the wire
controller
1
Mode select button (MODE):
Press MODE button to select “COOL”, “DRY” , "HEAT", or "FAN ONLY" mode.(HEAT is invalid for
COOL ONLY wire controller.)
AUTO
COOL
DRY
HEAT
FAN
2
Fan speed button (FAN SPEED)
Press FAN SPEED to select fan speed from "AUTO", "LOW"," MED" , and "HIGH”. NOTE: some air
conditioners have no MED fan speed, and then the MED is regarded as HIGH.
3
Economical operation displays:
Press ECONOMICAL to display economical operation, if press ECONOMICAL again then the display
disappears
4
Lock display
Press LOCK to display the icon of LOCK. Press the button again then the icon of LOCK disappears. In
the mode of LOCK, all the buttons are invalid except for LOCK button.
5
CLOCK display.
Usually display the clock set currently. Press the button CLOCK for 4 seconds, the HOUR part will flash,
press button ▲ and ▼ to adjust HOUR. Press the button CLOCK again, the minute part flash, press
button▲ or▼ to adjust MINUTE. After clock set or clock operation, it must press CONFIRM to complete
the set.
6
TIMER ON/OFF display:
Display ON at the state of TIMER ON adjustment or after only set the TIMER ON; Display OFF at the
state of TIMER OFF adjustment or after only set the TIMER OFF; Display ON/OFF if simultaneously set
the mode of TIMER ON and TIMER OFF.
7
Temperature display area:
Usually display the set temperature. Press the buttons of and to set temperature, at the mode of FAN,
there is no figure display in the area.
Summary of Contents for KOU-12HFN1-QRC8
Page 1: ...Contents i Energy Related Products SUPER DC INVERTER SERIES Service Manual 2013 LFIS B 1309...
Page 2: ......
Page 4: ......
Page 17: ...Service Space Indoor Units 13 3 Service Space 1000mm 1000mm 1000mm 1000m m...
Page 23: ...Field Wiring Indoor Units 19 9 Field Wiring...
Page 31: ...Wiring Diagrams Indoor Units 27 KTB 24HWDN1 QRC4...
Page 42: ...Service Space 38 Indoor Units 3 Service Space...
Page 44: ...Wiring Diagrams 40 Indoor Units KUE 36HRFN1 QRC8 A...
Page 47: ...Indoor Units 43 9 Field Wiring...
Page 50: ...Dimensions 46 Indoor Units 2 Dimensions...
Page 51: ...Service Space Indoor Units 47 3 Service Space...
Page 52: ...Wiring Diagrams 48 Indoor Units 4 Wiring Diagrams KCA2U 12HRFN1 QRC8 KCA2 18HRFN1 QRC8...
Page 56: ...52 Indoor Units 10 Field Wiring KCA2U 12HRFN1 QRC8 KCA2 18HRFN1 QRC8...
Page 58: ......
Page 61: ...Dimensions Console Type 57 2 Dimensions KFAU 12HRFN1 QRC8 KFA 16HRFN1 QRC8...
Page 62: ...Service Space 58 Console Type 3 Service Space...
Page 63: ...Wiring Diagrams Console Type 59 4 Wiring Diagrams KFAU 12HRFN1 QRC8 KFA 16HRFN1 QRC8...
Page 68: ...Field Wiring 64 Console Type 10 Field Wiring KFAU 12HRFN1 QRC8 KFA 16HRFN1 QRC8...
Page 74: ...Wiring Diagrams 70 Outdoor Units 4 Wiring Diagrams KOU 12HFN1 QRC8...
Page 76: ...Wiring Diagrams 72 Outdoor Units KOU 36HFN1 RRC4 KOU 36HFN1 RRC8 520 KOU 36HFN1 QRC8 5A0...
Page 77: ...Wiring Diagrams Outdoor Units 73 KOU 36HFN1 RRC8 5A0...
Page 102: ...Refrigerant pipe installation 98 Installation...
Page 110: ...Engineering of insulation 106 Installation cause leakage to damage the house decoration...