IX32 Wireless Ceiling PIR Detector User Guide
Front Case
Battery Box
(2PCS)
Installing Location
Hanging Panel
Back Shell
Infrared Lens
LED Indicator
Jumper Setting
Tamper Switch
X
X
X
Expansive Tube
Screw
#5 Battery
1.Take the screw, expansive
tube and 2 pcs #5 battery.
2.Turn over the alarm, anti-clockwisely
rotate the hanging panel,
and remove it.
3. Insert 2 pcs #5 battery in right
polari
ty.
5.Hold the device in ordinary grip, let the back
hole face to raisedpart of the panel to install,
then clock wisely whirl it the bottom, so the
device can be fixed.
4.
Make location hole as picture indicates,
knock the expansive tube in it, use screw
knife to make the screws entering, then
the panel can fix on the wall.
(1)Underline
and make hole
(1)Upward Installation
(2) Insert tubes
(2)Clockwisely Rotation
(3)Fix the panel
2.5~4.0m
Side looking
-
Max.6m
Down looking
-
360
Detection Range
- -
1
Ⅰ
.
Introduction
IX 32 Wireless Ceiling PIR Intrusion Detector, employs digital micro-control
Energy collected process and dynamic random time division technology.
By use of high precision cylindrical Fresnel lens, increase its energy
received efficiency. High sensitivity and accuracy combined with advanced
software technology, make it more effectively detect true invader, or other
competitors that may cause false alarm. Excellent detective and false-less
performance, optional pulse count, completely meets various environments,
reduce potential false alarm possibly, high performance compared to other
competitors, large capacity internal battery. Exclusive power saved solution,
it supports at least 2 years.
Picture 1 External View
Picture 2 Internal Structure
Ⅱ
.
Specification
Type: IX32
:
Detection Distance
6
@ 25
m
℃
:
RF Range
120m
:
Input Voltage
VDC(2PCS LR 6 1.5V AA Battery)
3
Current
5
A
Standby
5mA
Alarm
:
≤1 μ (
) ≤1
(
)
Detection Range:(as diagram )
Optional lens data
Infrared Area
:
12+12+6
Max. Detection Square
:
6
diameter
m
RF Frequency: 433.92MHz (Default)/868MHz
Alarm Output: LED indicator turns on >3s
Installing Method: Ceiling Mounted
Mounting Height 2 5~4m
: .
Operating Temperature: -20
~50
℃
℃
Storage Temperature: -20
~60
℃
℃
Dimension: (L*W*H)100*100*33.5mm
Ⅲ
.
Installation
3.1 Installation Guide
3.2 Installation Procedure
Don’t face hot/cold source
Avoid direct sunshine
Wired detector should be away
from high-pressure cable
Installation base should
be stable