Operation
8 --- 35
8.6
Faults: Possible cause --- Remedy
The removal of faults that are not explicitly described in this service
manual may only be carried out by KAESER or by an authorised
KAESER service agency.
8.6.1
Working temperature too high
Possible cause:
Remedy:
The distance from the cooling air inlet
or outlet is too small.
Keep to the minimum distance and en-
sure sufficient ventilation.
Insufficient cooling air flow.
Ensure sufficient ventilation.
Ambient temperature too high.
Arrange for a supply of cooler air or
move the machine to a cooler place
(see chapter 1.6).
If ducting is used for cooling air dis-
charge it could be too narrow or too
long.
Have an authorised KAESER service
agent install adequately sized ducting.
If the machine is air ---cooled, the fluid/
air cooler could be clogged.
Clean the fluid/air cooler (see chapter
9.13).
If the machine is water ---cooled, the
heat exchanger could be clogged by
deposits.
Have an authorised KAESER service
agent inspect, clean or replace the
heat exchanger as necessary.
Air inlet filter mats clogged.
Clean or replace the filter mats.
Fluid level too low.
Top up to the correct level with recom-
mended cooling fluid.
Check and clean the dirt trap strainer
in the fluid scavenge line.
Thermostatic valve not functioning cor-
rectly.
Check valve spring and activating pis-
ton. Replace defective parts.
Wrong cooling fluid used.
Drain off old cooling fluid and replace
with recommended type.
Ask an authorized KAESER service
agent for recommendations on cooling
fluid types.
Fluid filter clogged.
Change the fluid filter (see chapter
9.11).
Airend defective.
Have the airend checked by an autho-
rised KAESER service agent.
8.6.2
Motor overload protection relay trips
Possible cause:
Remedy:
Protection relay is defective or incor-
rectly set.
Check the wiring and reset the relay if
necessary.
Replace a defective overload relay.
Motor runs on two phases; motor de-
fective or one of the customer’s fuses
blown.
Check power supply and wiring.
Change fuse(s) or motor as necessary.
Summary of Contents for SK 19
Page 10: ...Technical Specification 1 6 ...
Page 19: ...Construction and Operation 5 15 ...
Page 20: ...Construction and Operation 5 16 ...
Page 64: ...Appendix 11 60 11 Appendix 11 1 Wiring Diagram ...
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......
Page 75: ......
Page 76: ......
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ......
Page 81: ...Appendix 11 77 11 2 Spare Parts List ...
Page 82: ......
Page 83: ......
Page 84: ......
Page 85: ......