Fig. 54 Draining the oil from the heat exchanger
1
Oil separator tank
7
Heat exchanger
8
Floor pan
9
Heat exchanger drain plug
10
Gasket
11
Underside of floor pan
1. Place the oil receptacle below the corresponding drain hole in the floor pan.
2. Unscrew the drain plug
9
at the heat exchanger and allow the cooling oil to drain into the re‐
ceptacle.
3. Fit a new gasket on the drain plug and screw it back in again.
Performing final work steps:
1. Replace the plug in the oil separator tank filling port.
2. Close the door.
Dispose of used oil and oil-contaminated working materials according to environmental pro‐
tection regulations.
Further information See chapter 10.4.2 for cooling oil filling.
10.4.4 Replacing the compressor oil filter
Material Spare part
Oil receptacle
Cleaning cloths
Precondition The machine is switched off.
The machine is fully vented, the pressure gauge reads 0 bar.
The machine has cooled down.
All compressed air consumers are disconnected and the air outlet valves are open.
The negative cable to the battery is disconnected.
CAUTION
Danger of burning from hot components and oil.
➤ Wear long-sleeved clothing and gloves.
10 Maintenance
10.4 Compressor Maintenance
126
Operator manual Portable compressor
M 64
No.: 9_5898 26 E
Option db
RAMIRENT