Advice can be obtained from KAESER SERVICE on determining suitable changing intervals.
➤ Check operating conditions and adjust intervals as necessary; log the results in table 36 for fu‐
ture reference.
Maximum permissible oil change interval
[operating hours/years]
Compressor oil
Favourable operating conditions
1)
My operating conditions
SAE 5 W30
1000/2
VDL 150
1000/1
FGP
1000/2
1)
Cool to moderate ambient temperatures, low humidity, average to high duty cycle.
Tab. 36 Compressor oil Change intervals
10.2.4 Regular service tasks
The table below lists necessary service tasks.
➤ Have an authorized KAESER SERVICE technician carry out service tasks.
➤ Have service tasks carried out punctually taking ambient and operating conditions into ac‐
count.
Interval
Service task
At the latest every
2 years
Replace the air filter element.
Up to 3000 h
Have cylinder head and valves checked.
Up to 12,000 h
Have the machine generally overhauled.
Up to 12 000 h,at the lat‐
est every 3 years.
Check for noisy motor bearings and replace as necessary.
Up to 36 000 h,at the lat‐
est every 6 years.
Have the plastic pipes and hose lines been replaced.
h = operating hours
Tab. 37 Regular service tasks
10.3 Maintaining the air cooler or fan cowl
According to machine model, it either has an air cooler of a fan guard.
Clogging causes overheating and machine damage.
Regular cleaning ensures reliable cooling of the machine and the compressed air. The frequency is
mainly dependent on local operating conditions.
10 Maintenance
10.3 Maintaining the air cooler or fan cowl
No.: 9_5752 24 E
Assembly and operating manual 1-stage piston compressor
EPC-G
67