CAUTION
Danger of short circuit
Damage to the machine electrics is possible.
➤ Use the «battery isolating switch» only when the machine is at standstill.
➤ Do not use the «battery isolating switch» as a main or emergency switch.
1. Switch off the «Controller».
2. Open the left-hand door.
3. Switch off the battery «battery isolating switch» when the instrument panel display is no longer
illuminated.
The battery is disconnected from the machine's electrical system.
4. Close the «compressed air outlet valves» on the air distributor.
5. Close the operating panel cover and all doors. Lock if necessary.
8.2.6 Shutting down in an emergency
In case of danger, immediately stop the machine by pressing the «Quick stop» button.
Use the «Quick stop» button to stop the machine only in emergencies.
Quick shutdown:
➤ Press the «Quick-stop» button.
■ The engine stops immediately.
■ The «Quick stop button »remains latched after being pressed.
■ The re-start inhibitor is activated (20 seconds).
■ The «Information key » and the «Stop key» are illuminated.
■ The «Acknowledge» key flashes.
Reactivating the machine:
When the fault has been cleared, the machine must be reset.
Precondition The fault has been rectified.
➤ Unlatch the «Quick-stop button».
➤ Confirm the message with the «Acknowledge key» .
The «Information» , «Stop» , and «Acknowledge» keys extinguish.
The machine can now be started again.
8.3 Setting parameters
Parameter setting and changing takes place in the controller settings menu.
■ Select
<Main menu => setting>.
■ See chapter 4.8.2 for using the settings menu.
■ Some menu options are password protected.
8
Operation
8.3
Setting parameters
82
Service Manual Screw Compressor
M170 SIGMA CONTROL MOBIL
No.: 9_9425 01 E