![KAESER KOMPRESSOREN M170 Service Manual Download Page 54](http://html1.mh-extra.com/html/kaeser-kompressoren/m170/m170_service-manual_3188024054.webp)
Display page
Figure
Motor data
4. Page
2,2 bar
23 °C
Turbo air pressure
Turbo air temperature
Tab. 52 Engine data display
Compressor data
The compressor unit operating data is presented on numerous display pages. With the aid of the
arrow keys, one can page through the menu guide between the display pages.
The following data are shown:
Display page
Figure
Compressor unit data
1. Page
88 °C
7,5 bar
Airend discharge temperature
Pressure in the oil separator tank
(OST)
2. Page
7,5 bar
5,0 bar
10,0 bar
Set pressure in the oil separator
tank (OST)
Tab. 53 Display of compressor operating data
4.8.2 SIGMA CONTROL MOBIL settings menu
Selecting the hand symbol (table 48, item
1b
) in the main menu will open the settings menu.
Password level
Entries and changes in the settings menu are only possible with the correct password.
The password level is reached by means of the "key" symbol in the individual menu views.
The password level is reset 3 minutes after the last key has been depressed. Temporary settings
are not saved and are lost!
There are more than one password levels
Password level Symbol Authorization
0
No password
■ Only user settings possible
1
Renter password
■ Engine basic settings.
■ Confirm maintenance carried out.
■ Temporary pressure increase of 1.5 bar above working pressure.
* Maximum machine working pressure