33
© 2017 Infinite Electronics, Inc., All Rights Reserved.
1.21.2 Minimum Limit
1.21.2.1 Minimum Limit Start
This is the starting point that spec level is applied over in this case 2000MHz.
1.21.2.2 Minimum Limit Stop
This is the end point that spec level is applied over in this case 2090MHz.
1.21.2.3 Minimum Limit Level
1.21.2.4 Limit label, type and result
The limit label shows the label you created in the limits menu, the down arrow shows this is a Minimum spec limit. There is
a result shown here also, between the start and stop points the trace has a Minima of -1.33
Figure 25 Minimum Spec Limit