4. Indoor unit installation
Indoor unit parts
Fig. 4.1 (applicable to KDI36, KDI42, KDI48 and KDI60)
• Upon delivery, the package should be checked and any
damage should be reported immediately.
• When handling the unit, take into account the following:
The unit is fragile, handle the unit with care.
• Keep the unit upright in order to avoid
compressor damage.
• When lifting the unit, always use protectors to prevent
belt damage and pay attention to the position of the
unit’s centre of gravity.
Safety precautions
WARNING
Securely install the indoor unit on a structure that can
sustain its weight. If the structure is too weak, the unit may
fall, causing personal injury, unit and property damage, or
even death.
CAUTION
Install the indoor and outdoor units, cables and wires at
least 1m from televisions or radios to prevent static or
image distortion. Depending on the appliances, a 1m
distance may not be sufficient.
DO NOT install unit in the following locations:
✕
Where oil drilling or fracking is taking place.
✕
Coastal areas with high salt content in the air.
✕
Areas with caustic gases in the air, such as near
hot springs.
✕
Areas with power fluctuations, such as factories.
✕
Enclosed spaces, such as cabinets.
✕
Areas with strong electromagnetic waves.
✕
Areas that store flammable materials or gas.
✕
Rooms with high humidity, such as bathrooms or
laundry rooms.
Air inlet
Return air
Air outlet
Supply air
Heat exchanger
Electric control
cabinet
Drain hose
Refrigerant
connecting pipe