EN
Configuration and Operation
KACO Operating Instructions blueplanet 15.0-20.0 TL3
Page 45
Filtering display data (daily view only)
1.
Open the web server.
2. Select daily view.
3. To show or hide measurements, select or deselect the corresponding checkboxes in the “Choose view” area.
Exporting data
1.
Filter the display data if necessary.
2. Select the display period if applicable (daily, monthly, yearly or overview).
3. Press the “Export data” button.
4. Save the file.
NOTE
Regardless of the display data selected in the “Choose view” area, an export file always contains all
measurement data and yield data available for the selected period
8.5
Performing the software update
You can update the software of the inverter to a new version using the integrated USB interface. Use a FAT32-format-
ted USB stick to do this. Do not use any storage media with an external power supply (for example: an external hard
disk).
NOTE
Ensure that the AC and DC inverter power supply is active. It is only possible to update all of the
inverter’s components to the most current software version in this operating state.
CAUTION
Damage to the inverter
The update can fail if the power supply is interrupted during the update process. Parts of the
software or of the inverter itself can then be damaged.
»
Never disconnect the DC and AC power supply during a software update.
»
Do not remove the USB stick during a software update.
Preparing for the software update
1.
Download the software update file from the KACO web site and store it on your hard disk.
2. Copy the update file (.KUF) onto the USB stick.
»
Perform software update.
NOTE
The update can take several minutes. The “Operating” LED flashes during the update process. The
inverter may restart several times.
The following message appears if the DC power supply is too low: “DC power supply too low! Perform
update anyway?”
In this case, select "No" and perform the update with a stable voltage supply.