Instruction manual Kabola KB-Series version 6, 2018
13
To connect the room thermostat for KB- Combi – Calorifier:
Before you connect the room thermostat with Frost Guard, use a 4-core insulated wire 0,75
mm2.
Remove the right plug (green arrow) which you can find at the backside of the Kabola
dashboard (figure 12).
Connect the 4 wires of the room thermostat at T1 and T2 and S3 and B4 in connection A
(figure 11) at the backside of the dashboard as shown on the sticker inside the connector.
Connect the wires inside the room thermostat (Fig. 6.1) to Q14 (T1) and Q11 (T2)
Connect the Frost Guard connections (Fig 6.1) of the room thermostat to connections Q21
(S3) and Q22 ( B4) and in the plug on S3 and B4 (figure 11) at the back of the dashboard.
If the room thermostat shows a tap on its display the tap water is switched on, if there’s no tap
visible on the display, tap water is switched off.
Q14 Q11 Q21 Q22
↓
↓
↓
↓
T1 T2 S3 B4
Figure 6.1
Figure 6
Right plug Fig. 12
Figure 11
Summary of Contents for Ecoline Calorifier
Page 1: ...User manual KB ECOLINE series English Ecoline serie CH Calorifier Combi...
Page 20: ...Instruction manual Kabola KB Series version 6 2018 20 Appendix A Technical specifications...
Page 21: ...Instruction manual Kabola KB Series version 6 2018 21 Appendix B Electrical diagram 230 V...
Page 22: ...Instruction manual Kabola KB Series version 6 2018 22 Appendix B Electrical diagram 230 V...
Page 24: ...Instruction manual Kabola KB Series version 6 2018 24 Appendix D Boiler parts model 2012 2016...
Page 28: ...Instruction manual Kabola KB Series version 6 2018 28 Spareparts list model 2016 2017...
Page 30: ...Instruction manual Kabola KB Series version 6 2018 30 Appendix F CE declaration...
Page 31: ...Instruction manual Kabola KB Series version 6 2018 31 Warranty Conditions...
Page 32: ...Instruction manual Kabola KB Series version 6 2018 32 Appendix G Guarantee conditions...