oPErAtInG MoDEs

Pressing any button first, you activate the display backlit. By another short press of the “ Menu “  button, 
you open the main menu in which you can choose operating modes.

(the Pr3 weekly program set by default, see page 4)

AUto

the thermostat works according to the weekly program settings (this program can be changed; for detailed 
description, see ProG, page 4).
Press twice the “ Menu “, choose the AUto mode by turning the “   “ and press the “ 

 “ button to confirm.

sMs form:  auto

Change of the mode to AUto. thermostat will be work acc. last setting weekly program.

sms

(default temperature setting of 21°C)

MAnU

the thermostat works according to the temperature setting until the next manual change.
Press twice the “ Menu “, choose the MAnU mode by turning the “   “ and press the “ 

 “ button to confirm“.

sms

sMs form:  Manu

Change of the mode to MAnU. thermostat will be keep last setting temperature.

(the anti-freeze temperature of 3 °C is kept – cannot be changed)

oFF

the thermostat is permanently switched off until the next manual change of the mode.
Press twice the “ Menu “, choose the oFF mode by turning the “   “ and press the “ 

 “ button to confirm.

sMs form:  off

Change of the mode to oFF. You can cancel the mode by the sMs: temp xx or Auto or Manu

sms

HolIDAY

the thermostat maintains the preset temperature until the preset date and selected time. After expiry of the 
preset period, it automatically returns to the AUto/ MAnU mode last selected before the holiday.

Press twice the “ Menu “ button, choose the   mode by turning the “   “ and press the “ 

 “ button to 

confirm. step by step, set the temperature which the thermostat should keep during the holiday, date and time 
of your return from the holiday. Change the values by turning the “   “ button and confirm each change by 
pressing the “ 

 “ button. 

After making the settings, press the “ 

 “ button to return to the basic screen.

note: the holiday mode can be cancelled any time by selecting another AUto or MAnU mode.

CloCK sEttInG

setting the current time and date. 
Press twice the “ Menu “ button, choose the CloCK mode by turning the “   “ button, 
and press the “ 

 “ button to confirm.

Change the values by turning the “   “ button and confirm each change by pressing the “ 

 “ button 

(the parameter modified is always flashing); pressing the “ 

 “ button, you return to the menu).

ProG

(ProGrAMMInG)

You can set 9 weekly programs with 6 temperature changes per day. the Pr1 and Pr2 programs are empty; 
Pr3 to Pr7 programs are set by default. the PrU and Prl are also set by default, 
intended for the EVEn/oDD week option (for details, see pages 4 and 6).

Const

(ConstAnts)

setting the control parameters. For a detailed description, see page 5.
Press twice the “ Menu “ button, choose the Const mode by turning the “   “ button, 
and press the “ 

 “ button to confirm.

AUTO  MOdE

MANU  MOdE

OFF  MOdE

HOLIdAY

SET  TEMP

SET  TIME

SET  HOUR

PROGRAMMING

CONSTANTS

Summary of Contents for 65-005

Page 1: ...Manual room thermostat KABOLA with gsm module ALWAYS A WARM WELCOME ON BOARD...

Page 2: ...anual mode page 3 8 Clock setting mode page 3 9 Holiday mode page 3 10 Permanent shut off page 3 11 Summer mode page 6 12 Boiler inspection indication page 8 13 External sensor connection indication s...

Page 3: ...2 Remove the control part from the bottom cover of the device Fig 1 3 Chip off the plastic piece in the middle of the bottom cover to lead in the conductors 4 Run the conductors through the hole and...

Page 4: ...l the preset date and selected time After expiry of the preset period it automatically returns to the AUTO MANU mode last selected before the holiday Press twice the MENU button choose the mode by tur...

Page 5: ...press the button to confirm TEST MOdE ON OFF Monday Tuesday Wednesday Thursday Friday Saturday Sunday program No 3 1 2 3 4 5 6 05 21 05 21 05 21 05 21 05 21 07 21 07 21 12 20 12 20 12 20 12 20 12 20...

Page 6: ...y PID CONTROL PI CONTROL HYSTERESIS CONSTANTS TEMP TEMP TYPE OF REGUL t t t t T Topen ON po ad teplota T Topen ON po ad teplota T p smo proporcionality t t t t t t T Topen ON po ad teplota T Topen ON...

Page 7: ...time at which you want the desired temperature Within two operating days the program ascertains the thermal constants of the room and then it switches the heating on in advance sufficiently The preli...

Page 8: ...which the message was sent 2 TO ANOTHER NR SMS will be sent back to the telephone number entered in the thermostat 3 bOTH NUMBERS SMS will be sent back to both telephone numbers combination options 1...

Page 9: ...locked To try to unlock them again you must exit the CONST mode and browse up the constant locked again Turning the button gradually enter four digits and confirm each setting with the 20 version res...

Page 10: ...Low batteries in the thermostat Noakcept Error indicated wrong SMS format etc SIGNAL GSM x Determines the signal strength at the place where the thermostat is located where x is a value within the ran...

Page 11: ...STERESIS preliminary heating start function short term change in the required temp manual mode MANU permanent switch off OFF HOLIDAY mode summer mode even odd week selection heating cooling mode selec...

Page 12: ...agen Denmark Farco AS Oslo Norway Nautikulma Oy Turku Finland Groothandel Francois Antwerp Belgium PK Fluvial Paris France Stal Elektronik Slovenia and Croatia Baltic Marine Group AS Tallinn Estonia S...

Reviews: