4.
KABI Digital meter oil control gun
INSTALLING EXTENSION AND NOZZLE ON METER
1. Thread extension tube fitting (2) into meter outlet with at least
three full turns. (FIG. 3). Do not use a twist/lock or manual shut-
off nozzle. You must use an automatic nozzle on the meter or
the meter could be damaged.
2. Open all dispense position shut-off valves (B, FIG. 1) and start
the pump to pressurize the system. See Operation, for proper
operation of meter. To ensure dispensing accuracy, purge all air
from the fluid lines and dispense valve before you use it.
DIGITAL METER INFORMATION
TECHNICAL DATA
Power supply
DC 3V
Flow Rate
0-30 l/min
Working Temperature
–10°C to +50°C
Min. Working Pressure
3 bar
Measure Accuracy
0.5%
Max. Working Pressure
70 bar
Default Measure Unit
L
Viscosity of Fluid
8-5000 mPa·s
Initial Preset Data
4 L
Inlet and outlet connections
1/2” BSP
THE ELECTRONIC GEAR METER
Consists of an oval gear and its chamber with the appropriate
connections to establish a controlled flow through the meter. The
basic meter is made of the measuring element and of the housing.
A 5-digit liquid crystal display, 4 units and battery indicator, shows
the exact amount of fluid dispensed. The unit is programmed at
the factory to dispense and totalize in L, GAL, PT and QT.
Low battery indicator is included.
2 buttons are included on the meter:
TOTAL
The Total button is used to choose a desired digit
or symbol.
RESET
The Reset button is the switching key to add [1] to
figures or symbols chosen.
FIG. 3
2
40385