Operating instructions
• Door is closed and locked.
• Door can be opened by a key command.
• OKI and HSK (light barriers) act as secondary switching element.
• If HSK (light barriers) is set permanently, after 30 seconds it is closed
at creepage speed.
• If DIP3 ON is set it will not be pushed to enable a manual unlocking.
• Hold-open time is 5 seconds (not adjustable).
• The delayed switchover to the operating mode NIGHT can be activated
by means of parameter Tvn. function: if the program selector switch
is changed to the operating mode niGhT from any random operating
mode, the internal radar will still remain active during the programmed
time Tvn (eXiT).
• Door functions in one-way traffic.
• According to settings of DIP2,
the locking will lock
after having reached
the CLOSeD position
.
• Door can be opened by key or OKI
• OKA and HSK act as secondary switching elements.
• Door is not locked.
• Door can be opened with key, OKI or OKA.
• All opening elements and HSK act as secondary switching elements.
• Door opens and remains unlocked without mains power.
• With reduced opening, the door will open completely.
• Operating mode OPEN is
not kept
as a proper operating mode on
terminals.
• Operating mode OPEN can be realised via operating mode MANUAL.
if a reduced OPen position should be kept with a rubber cable, a key
can be used.
• Programmable by means of D-BEDIX.
niGhT
eXiT
AuTOmATiC
mAnuAL
(OPen)
5.1.2
Operating modes
5.1.3
Reset
A reset causes a stop and unlocks the door, afterwards the drive unit activates a new
setting-up procedure.
• A reset can be activated by reset push button on key program switch or on control unit.
Alternatively, to activate reset function, push simultaneously (min 1 second) operating
modes mAnuAL and eXiT.
• A reset can be activated by the D-BEDIX.