4. If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.
5. Test lock operation several times before closing door.
CAUTION: When selecting a combination, do not use birthday or other predictable data
that could give correlation between the user and combination. Once the new combination
has been set, do not share the combination. It is a secret.
•
Valid Combination Entry - Double signal after valid six (6) digit combination is entered.
•
Invalid Combination Entry - Triple signal indicates the old combination is still valid.
KEYPAD BACKLIGHT
• Press either lightbulb icon
• Panel keys will remain lighted for approximately 8 seconds
• The backlight feature will not adversely affect battery life if done in conjunction with
normal anticipated keypad usage.
BATTERY LOW WARNING
• Repeated LED flashing and beeping during an opening indicates that the battery is low
and needs immediate replacement.
• Uses one (1) 9-Volt alkaline battery only. (Example:
Duracell™ or Eveready™ alkaline batteries.) It is
recommended that batteries be replaced at least once a
year.
If battery is depleted and will not allow lock to open,
follow instructions below. Lock contains a non-volatile
memory. Even with batteries removed, the lock will retain
all programming.
CHANGING YOUR BATTERY
1. Open the battery door (black plastic compartment cover
located at the bottom of the keypad) by gently pulling the
tab down and to the right.
2. Allow the battery and its attached leads to drop down and
out of the battery compartment. If it does not drop, gently pull on the battery until it
drops out.
3. Remove the connector by unsnapping it from the two terminals on the top of the
battery.
CAUTION! Hold on to battery terminal connector to avoid pulling the wires out of
the housing.
4. Press and hold the zero (0) key for ten (10) seconds before installing a battery.
5. Connect a new 9-Volt Alkaline battery to the battery clip.
6. Gently push the battery and the leads completely into the battery compartment.
7. Close the battery door by rotating it up and to the left, gently pressing the latch side
into place.
Mounting Instructions available at www.kaba-mas.com.
NOTE: Any audit features, the software features, features associated with peripheral devices
and systems, optional interconnect devices and their associated features, features involving
the use of user keys, the duress feature, monitoring features, remote features, and other
additional features have not been evaluated by UL. Models 8130 and 3190 keypads are not