15
E.
STANDARD OPERATING PROCEDURES
E-1
This lock is equipped with a standard break away clutch. In the “home
position,” the lever or thumb turn is horizontal to the floor with the ability
to “break away” down to a detented position as the lever or thumb turn is
rotated. This “break away” action protects internal components.
Note
: Before entering a code, the lever or thumb turn should be positioned
horizontal to the floor (home position).
(See Figure 17)
E-2
Enter the factory default Master PIN (access code) by depressing the
appropriate code buttons. With each button depression you should hear a
short audible beep, and see a green light at the top right of the number
pad. Once the last button in the code is depressed, you will hear a longer
audible beep and internal motor action releasing the locking device. At
this point, you have 5 seconds to retract the latch or the lock will time out
and go secure.
F.
PROGRAMMING:
F-1
You must change the master Code from the factory default to another
code to program the lock. For further information on how to program the
E-Plex 3000 Series Models, refer to the companion “E-Plex 5000/3000
Operation Manual.”
Figure 17
Summary of Contents for E-PLEX 3x65 Deadlatch/Exit Mortise
Page 1: ...INSTALLATION INSTRUCTIONS E PLEX 3X00 SERIES NARROW STILE LOCK...
Page 9: ...9 Notes...
Page 10: ...10 Notes...