Technical Manual
Design and function
19
04045524 - 08/2016
Kaba access manager 92 32
4.8
Registration units
Two registration units can be connected to the access manager via coaxial cables
(connections Ant. A and Ant. B). Make sure that the connection A is always connected
first and the connection B is connected after that.
Supported registration units
•
Kaba registration unit 90 00
•
Kaba registration unit 90 01
•
Kaba registration unit 90 02 (with PIN keypad)
•
Kaba registration unit 90 03
•
Kaba registration unit 90 04
The registration units to be used are assigned to the device when planning the sys-
tem in the Kaba exivo software via a door template.
Functional features
•
A registration unit allows contact-free reading of RFID media in LEGIC technol-
ogy.
•
The registration units are supplied with power via the coaxial cable.
Parameterization
The parameterization of the registration units is defined via the "door templates" in
the partner application (software).
Parameterizing information
For the two registration units, it is not possible to determine different configurations.
The configuration can be established via address A or address B and is valid for both
registration units.
External inputs, relays and vandal contact are not available.
4.9
Door templates
The access manager can be parameterized using different door templates.
Supported door templates
The number of available door templates is constantly expanded. The current door
templates are listed in the Kaba exivo partner application.
The following components can be connected to the access manager via the corre-
sponding door template:
•
Door opener
•
Magnetic lock
•
Automatic door
•
Electric lock
•
Motor lock
Functional features
•
In the Kaba exivo software, various door templates with the above-mentioned
components are predefined. The door template to be used is selected via the
Kaba exivo software and assigned to the corresponding access manager.
•
The components are supplied with power by the access manager.